AirTAC 3V2M · Valve Manifold Assembly

Airtac 3V2M Solenoid Valve 3V2MNOFI-11F

The AirTAC Airtac 3V2M Solenoid Valve 3V2MNOFI-11F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Initial stateNormally open
  • Port size1/8 in
  • Coil voltageDC12V
  • Electrical entryFlying lead (lead-out wire type)
  • Stations11
  • Flow (Cv)0.1
  • Series3V2M
$452.05 $466.95Save 3% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 3V2M manifold set voltage, station and exhaust option on one page All 3V2M manifold set codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 3V2M Solenoid Valve 3V2MNOFI-11F

Eleven is a station count the 3V2M range reaches without gaps: the 3V2MNOFI-11F sets eleven normally open 3/2 poppet valves on a single base with one shared PT1/8 supply and one wiring run for the flying-lead coils. Stations can be mixed or expanded on the same manifold concept if the machine grows later.

De-energised, every outlet passes air; energising the DC12V coil vents that station through the base's centralised exhaust port. Eleven coils at 7.0 W draw 77 W together, close to 6.4 A at 12 V in the worst case. Each valve is direct-acting with spring return and coaxial shut-off, flows Cv 0.1, is protected to IP65 and carries a manual override. The normally open state is an ordering decision: no field conversion, and no gasket flip, turns it into NC.

Airtac 3V2M Solenoid Valve 3V2MNOFI-11F Technical Specifications

ModelAirtac 3V2M Solenoid Valve 3V2MNOFI-11F
Series3V2M
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Initial stateNormally open
Item formComplete assembly — 11 valves on a shared base
ExhaustCentralised exhaust
Port size1/8 in
ThreadPT
Coil voltageDC12V
Electrical entryFlying lead (lead-out wire type)
Coil power7.0 W
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceNot rated for vacuum
Flow coefficientCv 0.1
Temperature-20 to 70 C
ConstructionCoaxial shut-off (poppet), base-mounted, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

The initial state cannot be changed after ordering. 3V2M uses a dedicated base gasket, and reversing or flipping that gasket does not convert NC to NO. Order the state you need up front.

Model Code: Airtac 3V2M Solenoid Valve 3V2MNOFI-11F

3V2MBody — sets the flow, the coil power and whether vacuum is rated.
1/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
NONormally open: air passes until the coil is energised.
DC12VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
IElectrical entry: I = flying lead, otherwise a DIN plug.
11F11 stations in one assembly, centralised exhaust.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V2M Solenoid Valve 3V2MNOFI-11F Is Used

precision_manufacturing

Leak-test fixture clamps

Eleven spring-return clamps close over castings on a leak-test stand; each normally open station holds its clamp position until the 12 V coil commands a vent.

science

Climate chamber vent array

An environmental chamber vents eleven zones by default; each NO valve shuts its zone vent only when its coil energises, all fed from one 12 V control rail.

shield

Sampling skid blow-down

On a gas sampling skid, relief lines stay open through normally open valves, so a power cut leaves every point venting - the fail-safe direction the NO state provides.

Is the Airtac 3V2M Solenoid Valve 3V2MNOFI-11F the Right Part?

Match five points before ordering: normally open initial state (fixed for life - the dedicated base gasket cannot be reversed to change it), DC12V coil, flying lead entry, eleven stations with centralised exhaust, and PT thread as the family standard (G and NPT are catalogue choices).

At Cv 0.1 this bank buys density, not flow: a station needing more should run an individual 3V2 (Cv 0.18 at 1/8 in, 0.19 at 1/4 in, vacuum-rated) or a 3V3 (Cv 0.62, 1/4 in, vacuum-rated), while 3V1 handles light duties at 3.0 W DC. Double-acting cylinders are 5-port territory - specify the AirTAC 4V series for those.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Blank any unused station on the base before pressurising.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V2M Solenoid Valve 3V2MNOFI-11F FAQ

Eleven 3/2 direct-acting spring-return poppet valves, Cv 0.1 each, operating pressure 0-0.8 MPa (0-114 psi), temperature -20 to 70 C, DC12V coils at 7.0 W (77 W bank worst case), IP65 (DIN 40050), PT1/8 ports, centralised exhaust, manual override per valve, air filtered to 40 um or finer without lubrication.

Centralised exhaust routes all eleven stations out through one base port, which keeps ducting and silencing simple. Choose the D (independent exhaust) variant instead when stations must vent separately - for example to stop one station's discharge back-pressuring another. State and station count are fixed at order either way.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 3V2M Solenoid Valve 3V2MNOFI-11F

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V2MNOFI-11F and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.