The AirTAC Airtac 3V2M Solenoid Valve 3V2MNOFI-19F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.
Nineteen normally open 3/2 stations on a single 3V2M base make the 3V2MNOFI-19F the densest assembly in this run: every coil at AC24V, every valve on a flying lead, one shared supply and one centralised exhaust path for the whole block. Rest state is flow - each outlet passes air until its solenoid is energised, then the spring return vents it, which is why NO manifolds are favoured on machines that must keep blowing, purging or releasing when control power drops.
Each valve is a direct-acting, single-solenoid coaxial shut-off (poppet) unit rated Cv 0.1 and IP65 (DIN 40050). Nineteen stations all energised draw 19 x 7 VA = 133 VA on the AC24V supply, so check your transformer margin before commissioning. Air must be filtered to 40 um or finer; lubrication is not required, and a manual override on each body speeds commissioning.
| Model | Airtac 3V2M Solenoid Valve 3V2MNOFI-19F |
|---|---|
| Series | 3V2M |
| Valve type | 3/2-way (3-port, 2-position) |
| Function | Direct-acting, single solenoid, spring return |
| Initial state | Normally open |
| Item form | Complete assembly — 19 valves on a shared base |
| Exhaust | Centralised exhaust |
| Port size | 1/8 in |
| Thread | PT |
| Coil voltage | DC12V |
|---|---|
| Electrical entry | Flying lead (lead-out wire type) |
| Coil power | 7.0 W |
| Operating pressure | 0-0.8 MPa (0-114 psi) |
| Vacuum service | Not rated for vacuum |
| Flow coefficient | Cv 0.1 |
| Temperature | -20 to 70 C |
| Construction | Coaxial shut-off (poppet), base-mounted, spring return |
| Protection | IP65 (DIN 40050) |
| Medium | Air, filtered by a 40 µm or finer element. Lubrication not required. |
Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| 3V2M | Body — sets the flow, the coil power and whether vacuum is rated. |
|---|---|
| 1/8 in | Port size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in. |
| NO | Normally open: air passes until the coil is energised. |
| DC12V | Coil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V. |
| I | Electrical entry: I = flying lead, otherwise a DIN plug. |
| 19F | 19 stations in one assembly, centralised exhaust. |
| PT | Port thread. PT ships from stock; G and NPT are available to order. |
A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.
That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.
It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.
Nineteen NO valves feed the air knife array of a tray washer, so knives keep blowing even during a control outage, with all exhausts collected at one silenced point.
A CNC line's chip-clearing jets sit on one 19-way base; each zone blows by default and is vented on command, keeping setup and tuning to single connections.
Safety interlock pins on a stamping press stay engaged on stored air via normally open stations; energising a station vents and releases it, one base wiring run for all nineteen.
Order the 19F assembly when nineteen fail-flow (NO) circuits share an AC24V control system and lead-out wiring is preferred to DIN sockets. Settle the five-order points first - initial state (NO, unchangeable after purchase), voltage (AC24V), entry (flying lead), stations (19) and exhaust (centralised here; choose a -D code if each station must vent separately). Thread is PT as the family standard, with G and NPT available to order.
When a particular station needs more than Cv 0.1, split the duty: keep the manifold for the low-flow points and put an individually ported 3V2 (Cv 0.18 at 1/8 in, 0.19 at 1/4 in, vacuum-rated) or a 3V3 (Cv 0.62, 1/4 in, vacuum-rated) on the heavy line. If the whole duty is light, 3V1 at 3.0 W DC cuts coil draw. Double-acting cylinders fall outside any 3/2 valve - use the AirTAC 4V series.
Confirm before you order
Nineteen 3/2 normally open valves, direct-acting, single solenoid, spring return, one base, flying leads, AC24V. Cv 0.1 per station, pressure 0-0.8 MPa (0-114 psi), temperature -20 to 70 C, coil power 7 VA AC (7.0 W DC types), IP65 (DIN 40050), PT1/8 ports, 40 um filtration, lubrication not needed, manual override fitted. 3V2M has no vacuum rating in the catalogue.
With no D suffix, all nineteen stations exhaust through the base's common path - one silencer, simpler pipework, but stations are not individually vented; order a -D code if you need separate exhausts. Normally open means flow continues when a coil is de-energised, chosen for fail-flow duties. The state is fixed at manufacture: reversing the 3V2M base gasket does not convert NO to NC, so order the correct state. These valves drive single-acting cylinders only; double-acting needs an AirTAC 4V 5-port valve.
Genuine AirTAC parts produced by the AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.