verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 3V2M · Valve Manifold Assembly

Airtac 3V2M Solenoid Valve 3V2MNOFI-8F

The AirTAC Airtac 3V2M Solenoid Valve 3V2MNOFI-8F is a genuine 3-port 2-position (3/2) solenoid valve with 1/8 in ports. It either feeds its outlet or vents it to exhaust, which is what makes it the valve for single-acting cylinders, on/off air blow, clamping, vacuum switching and pilot duty.

  • Valve type3/2-way (3-port, 2-position)
  • Initial stateNormally open
  • Port size1/8 in
  • Coil voltageDC12V
  • Electrical entryFlying lead (lead-out wire type)
  • Stations8
  • Flow (Cv)0.1
  • Series3V2M
$331.48 $343.39Save 3% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 3V2M manifold set voltage, station and exhaust option on one page All 3V2M manifold set codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 3V2M Solenoid Valve 3V2MNOFI-8F

Eight normally open 3/2 solenoid valves, pre-grouped on one 3V2M base: that is the 3V2MNOFI-8F in a line. Each valve is a direct-acting, single-solenoid unit with spring return and a coaxial poppet seat for clean shut-off, feeding or venting one outlet per station. While a coil is off, that outlet passes air; energise it and the station vents through the base's single centralised exhaust port.

Wiring is via flying leads (the I entry), so each coil arrives with pre-attached lead-out wires instead of a DIN socket - handy where a socket could work loose under vibration. The F voltage code is DC12V at 7.0 W per coil, so eight stations energised together load the supply with roughly 56 W, near 4.7 A at 12 V. Flow is Cv 0.1 per station through the base path, pressure 0-0.8 MPa, and protection is IP65 (DIN 40050).

Airtac 3V2M Solenoid Valve 3V2MNOFI-8F Technical Specifications

ModelAirtac 3V2M Solenoid Valve 3V2MNOFI-8F
Series3V2M
Valve type3/2-way (3-port, 2-position)
FunctionDirect-acting, single solenoid, spring return
Initial stateNormally open
Item formComplete assembly — 8 valves on a shared base
ExhaustCentralised exhaust
Port size1/8 in
ThreadPT
Coil voltageDC12V
Electrical entryFlying lead (lead-out wire type)
Coil power7.0 W
Operating pressure0-0.8 MPa (0-114 psi)
Vacuum serviceNot rated for vacuum
Flow coefficientCv 0.1
Temperature-20 to 70 C
ConstructionCoaxial shut-off (poppet), base-mounted, spring return
ProtectionIP65 (DIN 40050)
MediumAir, filtered by a 40 µm or finer element. Lubrication not required.

Figures follow the official AirTAC 3V2M catalogue. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

The initial state cannot be changed after ordering. 3V2M uses a dedicated base gasket, and reversing or flipping that gasket does not convert NC to NO. Order the state you need up front.

Model Code: Airtac 3V2M Solenoid Valve 3V2MNOFI-8F

3V2MBody — sets the flow, the coil power and whether vacuum is rated.
1/8 inPort size. M5, 06 = 1/8 in, 08 = 1/4 in, 10 = 3/8 in.
NONormally open: air passes until the coil is energised.
DC12VCoil voltage. A = AC220V, B = DC24V, C = AC110V, E = AC24V, F = DC12V.
IElectrical entry: I = flying lead, otherwise a DIN plug.
8F8 stations in one assembly, centralised exhaust.
PTPort thread. PT ships from stock; G and NPT are available to order.

What a 3/2 Valve Does

A 3/2 valve has three ports — supply, outlet and exhaust — and two states. It either feeds the outlet or vents it to exhaust, and that is the whole job.

That makes it the right valve for a single-acting (spring-return) cylinder, on/off air blow, a clamp, switching a vacuum generator or suction cup, and piloting a larger valve.

It cannot run a double-acting cylinder. A double-acting cylinder needs air alternately on two sides, which takes a 5-port valve — the AirTAC 4V series.

Where the Airtac 3V2M Solenoid Valve 3V2MNOFI-8F Is Used

air

Part-cooling nozzle bank

Eight cooling-air nozzles above an injection-moulding take-out robot keep blowing while the line idles and cut off the moment each DC12V coil is energised.

cable

Battery-fed agri robot

A 12 V lead-acid battery on a greenhouse row-closing cart feeds the flying leads straight from a fused distribution strip - no DIN sockets to seat in a dusty cab.

conveyor_belt

Bottling line stopper gates

Spring-return stopper cylinders on a bottle conveyor are fed air while idle and vent to release the bottles the instant each coil is energised.

Is the Airtac 3V2M Solenoid Valve 3V2MNOFI-8F the Right Part?

Choose the 3V2M family when you need many valves packed closely and can trade some flow for density: through the base each station is Cv 0.1, against a standalone 3V2's Cv 0.18 at 1/8 in or 0.19 at 1/4 in. Step up to 3V3 (Cv 0.62 at 1/4 in) where a circuit needs the most flow the 3V range offers, or down to 3V1 at 3.0 W DC for light, low-draw duties. A 3/2 valve cannot drive a double-acting cylinder - for those, move to the AirTAC 4V series.

Lock five points before ordering: normally open state, DC12V coil, flying-lead entry, eight stations and centralised exhaust, plus thread (PT is standard on this family; G and NPT are order options). The NO state is fixed at purchase - no gasket reversal or field change converts it to NC, so order NC if the outlet must be closed at rest.

Confirm before you order

  • ✓ Port size and thread (PT from stock; G / NPT to order)
  • ✓ Initial state — NC or NO, ordered up front
  • ✓ Coil voltage matches your controller output
  • ✓ Electrical entry — DIN plug or flying lead
  • ✓ Single valve, bare base, or complete assembly
  • ✓ Single-acting duty, not double-acting
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Stay within 0-0.8 MPa (0-114 psi) operating pressure.
  • check Match the coil voltage to your controller output.
  • check Use the manual override to test before powering up.
  • check Leave the exhaust port clear, or fit a silencer.
  • check Blank any unused station on the base before pressurising.
  • check Wiring by qualified personnel, per AirTAC documentation.

Airtac 3V2M Solenoid Valve 3V2MNOFI-8F FAQ

Each valve is a 3/2 direct-acting poppet type with a flow coefficient of Cv 0.1, operating pressure 0-0.8 MPa (0-114 psi), media temperature -20 to 70 C and IP65 (DIN 40050) protection. Coils are DC12V at 7.0 W, so eight stations energised together draw about 56 W - roughly 4.7 A at 12 V. Ports are PT1/8, with a manual override fitted for commissioning.

No. The initial state is fixed when the valve is made and ordered, and nothing done on site changes NO into NC. Reversing or flipping the dedicated base gasket does not convert the state - the catalogue states this explicitly. If your circuit must be closed at rest, order the NC version up front.

verified

Authorized Export Seller

Genuine AirTAC parts produced by the AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 3V2M Solenoid Valve 3V2MNOFI-8F

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 3V2MNOFI-8F and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.