AirTAC 4V Series · 5/2-way Solenoid Valve

Airtac 4V Solenoid Valves 4V11006C-W

The AirTAC Airtac 4V Solenoid Valves 4V11006C-W is a genuine 5/2-way single solenoid (spring return) solenoid valve with W ports and an effective area of 10.2 mm² (Cv 0.6). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.

  • Valve type5/2-way
  • FunctionSingle solenoid (spring return)
  • Port sizeW
  • Effective area10.2 mm²
  • Flow (Cv)0.6
  • Series4V100
$25.92 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 4V Solenoid Valves 4V11006C-W

The AirTAC 4V110-06C-W is a 5/2 single-solenoid directional valve built on the compact 4V100 body, wired for AC110V at 3.5 VA. With Cv 0.6 (effective area 10.2 mm2) and 1/8in PT tapered ports, it shifts compressed air between the two sides of double-acting cylinders and actuators rated around Dia16-32 mm bore. Energise the coil to switch the valve; the internal spring returns the spool the moment power drops, so the actuator stroke always follows the electrical signal one-for-one. Speed for this class: the spool cycles up to 5 times per second and responds in 0.05 s or less, enough for a Dia20 benchtop cylinder to complete short shuttle strokes at over a push-pull per second on clean, 40 um filtered air. The aluminium body weighs just 120 g, carries IP65 (DIN40050) protection, and the bare terminal-box entry lets you land your own conduit or wire channel. A manual override on the coil end lets maintenance staff stroke the valve with the control power off. Genuine AirTAC unit, sourced through authorised channels.

Airtac 4V Solenoid Valves 4V11006C-W Technical Specifications

ModelAirtac 4V Solenoid Valves 4V11006C-W
Series4V100 solenoid valve (spool type)
Valve type5/2-way
FunctionSingle solenoid (spring return)
Port sizeW
Exhaust portW
Effective area (Cv)10.2 mm² (Cv 0.6)
FluidAir (filtered by 40µm element)
Pilot typeInternal / external pilot
Operating pressure0.15 – 0.8 MPa
Proof pressure1.2 MPa
Max frequency5 cycle/sec
Response time≤ 0.05 s (activating)
Temperature-20 to +70 °C
Body materialAluminum alloy
Weight120 g

Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Flow & Coil Options

Effective area10.2 mm²
Flow coefficientCv 0.6
Response time≤ 0.05 s
Coil powerAC 3.5 VA · DC24V 2.8 W · DC12V 2.5 W
Protection / insulationIP65 (DIN40050), B-class
Voltage optionsDC24V, DC12V, AC110V, AC220V
Manual overrideYes (locking / non-locking)

Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.

Model Code: Airtac 4V Solenoid Valves 4V11006C-W

4VSolenoid valve, spool type, 4-series.
1Body size (4V100) — sets port & flow.
1Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3.
-WPort thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2".

Related: 4V110 (single), 4V120 (double), 4V130C/E/P (5/3 center). Add the voltage suffix when ordering.

Where the Airtac 4V Solenoid Valves 4V11006C-W Is Used

science

Microscope camera turret indexing

A small rotary actuator swinging a camera into position at 0.5 MPa needs only about 5 kgf torque-equivalent output - well inside the 10.2 mm2 spool - while the spring return guarantees the turret parks on the home port whenever the 110 V signal is cut.

build

Benchtop cap-press for cosmetic bottles

A Dia20 short-stroke press cylinder produces roughly 16 kgf push at 0.5 MPa; with a 5 cycle/s valve limit and 0.05 s response, the station can press caps at about two per second on repeat-run batches.

cable

Wire-harness sorting gate

A Dia16 kicker cylinder deflects harness bundles into sorting lanes; spring return clears the lane automatically on stop or fault, and the 120 g aluminium body bolts straight onto a small manifold beside the conveyor.

Is the Airtac 4V Solenoid Valves 4V11006C-W the Right Valve?

Step down only by port size: the 4V110-M5 shares the same 10.2 mm2 spool but uses M5 ports for tight-spaced, small-tube plumbing. Step up when your cylinder needs real force or speed: a Dia16 bore develops about 10 kgf push at 0.5 MPa on this valve, while a Dia32 bore wants roughly 41 kgf push at 0.5 MPa and faster cycling - there the 4V210-08 with Cv 1.0 is the correct neighbour. Function logic: choose single solenoid when the actuator should always park on de-energising, double solenoid when it must hold its last pulsed position, or a 4V130C/E/P 5/3 when you need a definite center state (note 5/3 versions drop to Cv 0.51 and 3 cycles/s). Pick this terminal-box AC110V version when your panel already runs 110 V control circuits and you prefer hard-wiring over pre-wired grommet leads. For replacement matching, confirm five points: body size 4V100, function digit 10, port and thread (1/8in PT here), coil voltage (AC110V), and electrical entry (terminal box). The valve also mounts on an AirTAC manifold base for grouped valve assemblies, so mixed configurations can share one air supply and common exhaust.

Quick checklist

  • ✓ Required flow (Cv) for cylinder & speed
  • ✓ Function: single / double / 5-3 center
  • ✓ Coil voltage (DC24 / AC220 …)
  • ✓ Port thread (M5 / 1/8 / 1/4 / 3/8 / 1/2)
  • ✓ Single valve or manifold base?
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 0.8 MPa operating pressure.
  • check Match coil voltage to your controller output.
  • check Use the manual override to test before powering.
  • check Fit silencers or fittings to the exhaust ports.
  • check Wiring by qualified personnel per AirTAC docs.

Airtac 4V Solenoid Valves 4V11006C-W FAQ

Flow: Cv 0.6, effective area 10.2 mm2. Response: 0.05 s or less, max frequency 5 cycles/s. Pressure: 0.15-0.8 MPa operating, 1.2 MPa proof. Coil: AC110V at 3.5 VA, insulation class B, IP65 housing. Weight 120 g. It directs air to double-acting cylinders of roughly Dia16-32 mm - about 10 kgf push at 0.5 MPa on Dia16, about 41 kgf on Dia32.

Only if the supply is actually 110 V AC. The coil power differs (3.5 VA either way at these two voltages, but the winding is not interchangeable), and applying 220 V to a 110 V coil burns it out within seconds. Match all five points when replacing: 4V100 body, function 10, 1/8in PT ports, AC110V coil, terminal-box entry - otherwise order the exact sibling code instead.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 4V Solenoid Valves 4V11006C-W

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 4V11006C-W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.