verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC20008MC1W

The AirTAC Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC20008MC1W is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$78.60 $84.23Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC20008MC1W

GC20008MC1W is an AirTAC G-series three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator supplied as a matched 200-size set. This configuration is threaded PT1/4 (1/4 in PT, with G and NPT available as catalogue options), carries the finer 5 um filter element (the W option), is set up for manual draining of the filter bowl, and includes a round pressure gauge with MPa scale. In use, the filter removes water and fine particulate, the regulator holds downstream pressure steady, and the lubricator meters oil mist into the air line.

This is a genuine AirTAC part. The G series is offered in 200, 300, 400 and 600 sizes covering progressively larger ports and flow, with automatic, manual or differential-pressure draining, standard 40 um or 5 um filtration, gauge scale choices and G (BSPP) or NPT threads. Rated-flow figures are published as curves rather than a single number, so we confirm sizing and datasheet values on request.

Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC20008MC1W Technical Specifications

ModelAirtac B52-GC Copper-Free Air Source Treatment Component B52-GC20008MC1W
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (PT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC20008MC1W

GC200G-series F.R.L. combination, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/4" · 5 µm
One size upGC300
Two-unit equivalentGFC200-08
Build orderFilter → regulator → lubricator

Where the Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC20008MC1W Is Used

science

Laboratory pneumatic fixtures

Clean, regulated, lubricated air for test-rig clamps and actuated fixtures, where the 5 um element keeps fine debris out of precision instrument valves.

valve

Paint-spray gun supply

Point-of-use preparation at a spray booth drop: the regulator pins gun pressure, the fine 5 um element guards against particulate in the finish, and the lubricator is skipped or bypassed where oil-free air is preferred.

view_module

Pick-and-place gripper module

Air preparation for the vacuum ejectors and gripper cylinders on a modular handling cell, with 5 um filtration protecting small pilot valves.

Is the Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC20008MC1W the Right Station?

Size and port step up together: the 200 body with 1/4 in PT suits compact supply lines, while 300, 400 and 600 sizes serve higher-demand circuits - match the step to the flow your line needs. This set uses manual draining, which is simple and low-cost but relies on an operator; automatic (A) or differential-pressure draining is available. The 5 um (W) element is the finer choice for sensitive downstream equipment; the standard 40 um element suits general actuator supply. The round gauge here reads in MPa, with psi and bar scales orderable. PT thread is standard on this code; G (BSPP) and NPT are catalogue options. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.

Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC20008MC1W FAQ

AirTAC publishes G-series performance as flow curves rather than a single rated figure, so no one number covers every condition. Tell us your inlet pressure and required consumption and we will confirm sizing from the datasheet on request.

The standard 40 um element suits general actuator and tool supply. The W option filters to 5 um and is the better choice ahead of precision valves, instrumentation or finishing equipment. This code carries the W element; the plain suffix is the 40 um version.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC20008MC1W

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GC20008MC1W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.