AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC20008MLC1W

The AirTAC Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC20008MLC1W is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$78.60 $84.23Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC20008MLC1W

The GC series is AirTAC's three-unit F.R.L. combination: a separate air filter, a pressure regulator and a lubricator assembled as one set, so the compressed air stream is cleaned, regulated and oil-mist lubricated in sequence. This GC200 size is fitted with 1/4 in. PT ports, a 5 um filter element (the finer option instead of the standard 40 um), a manual drain on the filter bowl, the low-pressure (L) regulator type and a round pressure gauge reading in MPa. The filter and lubricator bowls are polycarbonate on the 200 size.

This is a genuine AirTAC part. The G series spans 200, 300, 400 and 600 sizes with 1/8 in. to 1 in. ports, and is offered with your choice of drain type, filter grade, gauge style and scale, and PT, G (BSPP) or NPT threads. Maximum working pressure is 1.0 MPa (145 psi) and the temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so we confirm flow and datasheet figures for your application on request.

Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC20008MLC1W Technical Specifications

ModelAirtac B52-GC Copper-Free Air Source Treatment Component B52-GC20008MLC1W
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (PT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC20008MLC1W

GC200G-series F.R.L. combination, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/4" · 5 µm
One size upGC300
Two-unit equivalentGFC200-08
Build orderFilter → regulator → lubricator

Where the Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC20008MLC1W Is Used

build

Pneumatic impact tools at assembly benches

Filters the shop air to 5 um, holds a steady low setpoint and meters oil mist into the air line feeding impact wrenches and ratchets, protecting the tool internals on a manual-drain maintenance round.

settings_input_component

Small packaging machine air circuits

A compact three-in-one conditioning point for carton sealers and wrapper clamp cylinders, with the round MPa gauge letting operators verify supply pressure at a glance.

air

Air-actuated paint spray lines

The finer 5 um element plus lubrication suits spray guns and air motors in a finishing cell, where clean, correctly lubricated air keeps finish quality consistent.

Is the Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC20008MLC1W the Right Station?

The 200 size with 1/4 in. PT ports is the compact step in the G series; if your line draws more air, step up to GC300/GC400 for larger ports and higher flow. Drain options are differential-pressure (default), automatic (A) or manual (M) - this model is manual, so an operator drains the bowl as part of routine checks. The W element filters to 5 um for sensitive downstream equipment; leave it off for the standard 40 um. Gauge choices are the embedded square gauge or the external round gauge (this model), in MPa, psi or bar scale. Thread is PT as standard; G and NPT are catalogue options. A mounting bracket is optional.

Flow is published as curves, not a single rated figure, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.

Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC20008MLC1W FAQ

AirTAC publishes flow for the G series as performance curves rather than a single rated figure, so there is no one number we can quote honestly. Tell us your application and we will confirm the flow and datasheet figures for you on request before you order.

L marks the low-pressure regulator type. Because this unit has a manual drain, the setpoint range is 0.05-0.9 MPa (7-130 psi). The gauge supplied reads in MPa; psi or bar scales are available in the same code position if you prefer.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC20008MLC1W

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GC20008MLC1W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.