AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC20008MLNW

The AirTAC Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC20008MLNW is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$54.78 $59.83Save 8% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC20008MLNW

GC20008MLNW is an AirTAC GC-series three-unit F.R.L. set for compressed air: a separate filter, pressure regulator and lubricator supplied as three units. This 200-size configuration is decoded with a PT1/4 (1/4 inch) port, a manual drain on the filter bowl, the 5 um filter element (W option) and the low-pressure regulator type, and it is ordered without a gauge. The filter and lubricator bowls on this 200 size are polycarbonate (PC).

This is a genuine AirTAC part. The GC series is also available in 300, 400 and 600 sizes with larger ports, differential-pressure, automatic or manual drain, 40 um standard or 5 um filtration, standard or low-pressure regulation, embedded square or external round gauges with MPa, psi or bar scales, and G (BSPP) or NPT threads in place of the PT standard. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so we confirm datasheet and sizing figures on request.

Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC20008MLNW Technical Specifications

ModelAirtac B52-GC Copper-Free Air Source Treatment Component B52-GC20008MLNW
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (PT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC20008MLNW

GC200G-series F.R.L. combination, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/4" · 5 µm
One size upGC300
Two-unit equivalentGFC200-08
Build orderFilter → regulator → lubricator

Where the Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC20008MLNW Is Used

science

Bench-top test rigs

Supplying pneumatic test fixtures and sample clamps on a lab or QC bench, where the 5 um element keeps fine valves and orifices clear at a low regulated pressure.

settings_input_component

Instrument panel actuation

Feeding small control valves and actuators inside a machine pneumatic sub-panel, with fine filtration ahead of close-tolerance internals and lubrication where seals need it.

air

Air nozzles on handling equipment

Conditioning supply to air nozzles and small air-bearing points on pick-and-place handling equipment where particulate must be kept out of tight gaps.

Is the Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC20008MLNW the Right Station?

Across the GC range of 200, 300, 400 and 600 sizes, this 200 set with its 1/4 inch PT port serves lighter branch lines; step up a size when demand calls for more flow. Drain is manual (M), with automatic and differential-pressure drains available as catalogue options. The W code selects the 5 um element over the 40 um standard, L selects the low-pressure regulator type (confirm its exact adjustment range with us), and N means no gauge. Thread is PT as standard, with G (BSPP) and NPT available to order.

Because flow is published as curves rather than a single rating, ask us to confirm sizing against your line pressure and downstream demand before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.

Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC20008MLNW FAQ

AirTAC publishes flow for this series as curves rather than a single rated figure, so we do not quote one number here. Send us your line pressure, downstream demand and allowed pressure drop, and we will confirm the sizing and the datasheet on request.

The W in the code fits a 5 um element, suited to sensitive valves, spray work and instrumentation where finer particulate removal matters. The 40 um standard element remains the right choice for general cylinders and air tools, and both grades are catalogue options on this series.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC20008MLNW

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GC20008MLNW and will confirm price, stock and lead time — usually within 7-8 hours.