The AirTAC Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC30008LNW is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$82.02 $87.75Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC30008LNW

GC30008LNW is an AirTAC G-series three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator built as one 300-size set with PT1/4 ports. The filter stage removes water and particulate down to 5 um (the W fine-grade element), the regulator is the low-pressure type variant and, with the differential-pressure drain fitted here, adjusts 0.15-0.9 MPa (20-130 psi), and the lubricator meters oil mist into the air line. This code carries no pressure gauge (N) and the standard PT thread.

This is a genuine AirTAC part. The GC series is offered in 200, 300, 400 and 600 sizes, with PT as the standard thread and G (BSPP) or NPT as catalogue options, a choice of differential-pressure, automatic or manual drain, and 40 um standard or 5 um filter elements. Flow is published as curves rather than a single rating, so we confirm sizing and datasheet figures on request.

Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC30008LNW Technical Specifications

ModelAirtac B52-GC Copper-Free Air Source Treatment Component B52-GC30008LNW
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC30008LNW

GC300G-series F.R.L. combination, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-08 filter, GR300-08 regulator and GL300-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/4" · 5 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-08
Build orderFilter → regulator → lubricator

Where the Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC30008LNW Is Used

precision_manufacturing

CNC machining centers

Feeding the clamp fixtures, tool-change cylinders and air-blast nozzles on a CNC machining center, where the 5 um element helps keep fine debris out of pilot valves and actuators.

conveyor_belt

Carton sealing lines

Supplying filtered, regulated, lubricated air to case erectors and carton sealers on a packaging conveyor, with the regulator holding a steady setting for repeatable cylinder strokes.

build

Pneumatic assembly benches

Point-of-use treatment at assembly stations running impact wrenches and nutrunners, where the lubricator meters oil mist into the tool air supply through a 1/4 in drop.

Is the Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC30008LNW the Right Station?

Size 300 with 1/4 in PT ports is a mid-range step in the G-series; drop to size 200 for compact branches or step up to 400/600 for larger mains. Drain choice matters: this unit uses the differential-pressure drain; order M for manual bleeding on a maintenance round or A for automatic draining. The 5 um W element is the right pick when finer particulate control is wanted; the standard 40 um element is available. If you need a pressure readout, choose a code with the gauge position set (C round or F square, scale 1 MPa, 2 psi or 3 bar). PT thread is standard; specify G (BSPP) or NPT to match existing piping, and max inlet pressure is 1.0 MPa (145 psi) with -5 to 70 C operation. Flow is published as curves, not a single rating - ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-08 regulator with a GF300-08 filter on that branch.

Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC30008LNW FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so no single flow number is quoted here. Send us your line pressure and air demand and we will confirm sizing against the datasheet on request.

The N in GC30008LNW means the set is built without a gauge. If you want a readout, select a GC code with the gauge position left blank (gauge included) or with C for a round gauge or F for a square gauge, in MPa (1), psi (2) or bar (3) scale.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC30008LNW

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GC30008LNW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.