verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GR200 · Air Pressure Regulator

Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20006JC1K

The AirTAC Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20006JC1K is a genuine G-series air pressure regulator. It holds a stable downstream pressure over the range 0.05 - 0.9 MPa (7 - 130 psi) with PT1/8" ports, and ships with a pressure gauge. A regulator does not filter the air — put a GF filter upstream, or use a GFR filter regulator, when water and particulate must also be removed.

  • TypePressure regulator
  • Port sizePT1/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Pressure typeStandard type
  • Pressure gaugeFitted
  • Reflux valveFitted
  • ThreadPT
  • BracketSupplied without bracket
$59.53 $64.69Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20006JC1K

The GR20006JC1K is an AirTAC GR-series air pressure regulator in the 200 size with a 1/8 inch PT port, fitted with the K reverse/check valve option. It regulates downstream pressure only - there is no filter, bowl or lubricator in this family - with a standard adjustment range of 0.05-0.9 MPa (7-130 psi), a maximum inlet pressure of 1.0 MPa (145 psi) and a working temperature range of -20 to 70 C. The J selects the no-bracket option and C1 provides an external round gauge on an MPa scale.

This is a genuine AirTAC part. The GR series covers 200/300/400/600 sizes with 1/8 to 1 inch ports, G (BSPP) and NPT thread options, a low-pressure type (L) up to 0.4 MPa, and panel-mountable bodies; the check valve is ordered as the K option. Flow appears in the catalogue as curves, so we confirm flow and datasheet details on request.

Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20006JC1K Technical Specifications

ModelAirtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20006JC1K
SeriesGR200 pressure regulator
Port sizePT1/8" (PT thread)
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
BracketSupplied without bracket
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-20 to +70 °C
Pressure gaugeFitted — round, MPa scale
Reflux valveFitted (reverse flow permitted)
MountingPanel mounting; optional fixing bracket

Specifications follow the official AirTAC G-series air-preparation data. Note the GR temperature range is -20 to +70 °C, wider than the other G-series units. A regulator has no bowl and no filter element, so there is no filtering grade. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20006JC1K

GR200G-series pressure regulator, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Standard type — 0.05 - 0.9 MPa (7 - 130 psi). Blank is standard, L is the low-pressure type.
JSupplied without bracket.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, type, bracket, gauge, gauge shape, scale, thread, reflux — a blank position takes the default. Example: GR300-08LNK is a 300 body, PT1/4", low-pressure type, no gauge, with reflux valve.

Size Class

  • GR200PT1/8" - PT1/4"
  • GR300PT1/4" - PT1/2"
  • GR400PT3/8" - PT1/2"
  • GR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure.

This modelGR200 · PT1/8" · 0.05 - 0.9 MPa (7 - 130 psi)
One size upGR300
Line orderFilter first, then regulator, then lubricator

Where the Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20006JC1K Is Used

valve

Pneumatic circuit with a held downstream branch

Regulate a branch where the K check valve is specified in the circuit design, keeping the regulator-and-valve pairing the schematic calls for on a 1/8 inch supply line.

conveyor_belt

Guide-rail and gate cylinders on conveyor lines

Set consistent pressure for line guides, stop gates and diverters so product handling stays gentle and repeatable along the conveyor.

engineering

Pilot-air control skids built to order

Drop into assembled control skids where the engineer has specified a regulator with a check valve and a no-bracket, panel-integrated installation.

Is the Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20006JC1K the Right Regulator?

Use this code when you want the 200-size regulator's 1/8 inch port plus the K reverse/check valve and a no-bracket (J) build with an external round MPa gauge. If you do not need the check valve, choose the same code without K; if you want the bracket, drop the J. Gauge alternatives are the embedded square gauge or a round gauge on psi (2) or bar (3) scale. PT is the standard thread; G (BSPP) and NPT are orderable options. Flow is published as curves rather than a single rating, so let us confirm sizing from the datasheet for your application before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Standard 0.9 MPa or low-pressure 0.4 MPa
  • ✓ Gauge fitted, or order N without
  • ✓ Gauge shape C round / F square
  • ✓ Scale MPa (1), psi (2) or bar (3)
  • ✓ Reflux valve needed, order K
Ask an Engineer

Installation & Maintenance Notes

  • check Install downstream of the filter, following the airflow arrow.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Set pressure while air is flowing, then lock the knob.
  • check Adjust within 0.05 - 0.9 MPa (7 - 130 psi) only.
  • check Operating range -20 to +70 °C.
  • check Panel-mount or use the fixing bracket; do not hang it on tubing.

The reflux valve lets air flow back through the regulator, which is useful when downstream volume must vent quickly. A regulator does not remove water or particulate; that is the filter's job.

Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20006JC1K FAQ

AirTAC states GR flow as curves, not as a single rated number, so we do not quote a rated flow here. Send us your flow and pressure conditions and we will confirm the sizing and check-valve details from the datasheet on request.

K is the option that fits a reverse/check valve to the regulator. Codes without the K are supplied without it. If your schematic or application calls for a check valve on the regulator, select the K version; otherwise the plain GR20006JC1 is the equivalent unit.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20006JC1K

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GR20006JC1K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.