verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC CMS · Reed switch cylinder sensor

Airtac CMS Reed Switch Cylinder Sensors CMSE-M08030

The AirTAC Airtac CMS Reed Switch Cylinder Sensors CMSE-M08030 is a genuine CMS magnetic position switch. It senses the magnet ring in a pneumatic cylinder's piston and signals when the piston reaches that point, giving a 2-wire output on 5-240 V AC/DC with a m8 connector. It only works on a cylinder that carries a piston magnet.

  • TechnologyReed (magnetic contact)
  • Output2-wire
  • Supply voltage5-240 V AC/DC
  • ProtectionIP64
  • Profile (groove fit)E
  • Lead / connectorM8 connector
  • VersionStandard
  • RequiresMagnet-equipped cylinder
$15.53 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac CMS Reed Switch Cylinder Sensors CMSE-M08030

This is the M8-connector version of AirTAC's CMSE reed family. The body carries a magnetic reed element - a true mechanical contact rather than solid-state electronics - and seats in the groove of a magnet-fitted AirTAC cylinder. Wiring leaves as an M8 connector on a 3 m pigtail, ready to mate with standard pre-wired M8 cordsets. The circuit is 2-wire, the contact switches 5-240 V AC/DC, and the general housing is IP64. Profile E sets the groove fit.

The connector is the maintenance win: to change a cylinder you unplug at the M8 instead of cutting and re-terminating a lead, and a damaged cordset swaps in seconds. Three metres of pigtail reaches an I/O block or junction box mounted well away from the cylinder. Note the reed contact is mechanical - tolerant of AC and DC, but a wearing part under very fast cycling. Profile E must seat correctly in your cylinder's groove, so confirm the series with us before ordering.

Airtac CMS Reed Switch Cylinder Sensors CMSE-M08030 Technical Specifications

ModelAirtac CMS Reed Switch Cylinder Sensors CMSE-M08030
FamilyCMS — Reed switch cylinder sensor
TechnologyReed (magnetic contact)
Output2-wire
Outputs in this family2-wire contact
Lead / connectorM8 connector
Supply voltage5-240 V AC/DC
Protection ratingIP64
VersionStandard version
Profile letterE (cylinder-groove fit)
Profiles in this familyE, G, H, J
DetectsPiston magnet ring inside the cylinder

A reed contact switches a wide window, 5-240 V AC or DC, which is why it suits AC circuits and relay logic. IP64. The CMS range has no RW / IP68 option - that belongs to DMS and EMS. Switching distance, response time, current rating, voltage drop, LED behaviour, contact life, weight and dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac CMS Reed Switch Cylinder Sensors CMSE-M08030

CMSReed switch cylinder sensor — reed (magnetic contact).
EProfile letter: the mounting / groove type that fits a particular cylinder body. This family offers E, G, H, J. It is a fit code, not a performance grade.
M08030M8 connector. 020 / 030 / 050 / 100 are 2 / 3 / 5 / 10 m flying leads; M08 and M12 are M8 / M12 connector versions.
(blank)Standard version. On a CMS the suffix -H is the high-temperature version — do not confuse it with the H profile letter.

We do not hold the full profile-to-cylinder-series table, so confirm the profile letter against your cylinder model before ordering — send us the cylinder part number and we will check the fit.

Which Family Do You Need?

  • DMSElectronic, 2-wire / NPN / PNP, DC
  • EMSMini electronic, 2-wire only, DC
  • CMSReed contact, 2-wire, 5-240 V AC/DC

The split is electrical, not quality. Solid-state DMS and EMS are DC-only and suit modern PLC inputs; the reed-based CMS switches a much wider window, so it is the one for AC circuits, relay logic and older panels. The RW (IP68) option exists on DMS and EMS only.

This switchCMSE · 2-wire · 5-240 V AC/DC
Consider DMSthe solid-state range with NPN / PNP 3-wire outputs (DC only)
Consider EMSthe mini 2-wire solid-state switch (DC only)
Mounting partsF-MQ (round body), F-ACT (tie-rod)

Where the Airtac CMS Reed Switch Cylinder Sensors CMSE-M08030 Is Used

conveyor_belt

Pallet diverter station

Position proof on the diverter cylinder, plugged straight into a multi-port M8 I/O block beside the conveyor.

warehouse

AS/RS shuttle clamp

End-of-stroke signal on shuttle clamp cylinders, where the 3 m pigtail reaches the junction box on the lift mast.

handyman

Serviceable press tooling

Quick-disconnect M8 lets toolsetters exchange clamping cylinders without opening the control cabinet.

Is the Airtac CMS Reed Switch Cylinder Sensors CMSE-M08030 the Right Switch?

Pick the M08030 when your machine is already cabled with M8 cordsets, or when the switch sits far from the panel and you want one continuous run. Reed versus electronic comes down to the circuit: this contact accepts AC or DC from 5 to 240 V with no polarity, while a DMS electronic switch is DC-only. If you would rather terminate cable yourself, the 030 flying-lead code gives the same switch with a bare 3 m lead. Every CMS needs a magnet-equipped cylinder, and profile E has to match the groove.

Quick checklist

  • ✓ Cylinder has a piston magnet
  • ✓ Profile letter fits your cylinder groove
  • ✓ Output matches the PLC input (2-wire)
  • ✓ Supply rail is 5-240 V AC/DC
  • ✓ Lead length or M8 / M12 connector
  • ✓ High temperature? Use the -H version
Ask an Engineer

Installation & Wiring Notes

  • check The cylinder must carry a piston magnet — a plain cylinder cannot be sensed.
  • check Slide the switch along the groove to the stop position, then lock it.
  • check Keep the supply within 5-240 V AC/DC.
  • check A reed contact suits AC or DC; observe the load limits on the datasheet.
  • check Keep the lead clear of moving parts; use the RW type where it must flex.
  • check Rated IP64 — protect it beyond that rating.

Use the F-MQ bracket on round-body cylinders and F-ACT on tie-rod cylinders where there is no groove to seat the switch. Both are ordered separately from the switch. Switching distance and mounting dimensions come from the factory datasheet — ask us for the sheet that matches your cylinder.

Airtac CMS Reed Switch Cylinder Sensors CMSE-M08030 FAQ

Type: magnetic reed with a mechanical contact, not solid-state. Output: 2-wire. Supply: 5-240 V AC/DC. Protection: IP64, general type. Wiring: M8 connector on a 3 m pigtail. The profile letter E is the fit code for the cylinder groove.

The connector lets you unplug the switch for cylinder service and replace a damaged cable without re-terminating anything - valuable on machines where access is awkward. The 3 m pigtail also spans the distance to a remote I/O block. A flying-lead version is cheaper but must be cut, wired and re-made at every change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac CMS Reed Switch Cylinder Sensors CMSE-M08030

Send us the quantity, your cylinder model (so we can confirm the profile fit) and the destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for CMSE-M08030 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.