The AirTAC Airtac DMSG Electronic Sensor DMSG-NC12 is a genuine DMS magnetic position switch. It senses the magnet ring in a pneumatic cylinder's piston and signals when the piston reaches that point, giving a npn 3-wire output on 5-30 V DC. It only works on a cylinder that carries a piston magnet.
An electronic solid-state position switch, the DMSG-NC12 detects the magnet in the piston of a suitably equipped AirTAC cylinder. It delivers NPN 3-wire output - the sinking configuration PLC input cards expect - from a 5-30 V DC supply, with IP64 general protection. The C12 in the wiring position is a factory connection code not defined in our published data; its exact termination will be confirmed from the datasheet on request.
Solid-state switching means the output has no mechanical contact to wear or bounce, so repeated fast strokes do not erode the sensing element the way a reed contact can eventually fatigue. The G profile letter only fixes the body shape that seats in the cylinder groove - match it to your cylinder before ordering.
| Model | Airtac DMSG Electronic Sensor DMSG-NC12 |
|---|---|
| Family | DMS — Electronic cylinder switch |
| Technology | Electronic (solid-state) |
| Output | NPN 3-wire |
| Outputs in this family | 2-wire, NPN 3-wire or PNP 3-wire |
| Lead / connector | See datasheet |
| Supply voltage | 5-30 V DC |
|---|---|
| Protection rating | IP64 |
| Version | Standard version |
| Profile letter | G (cylinder-groove fit) |
| Profiles in this family | E, G, H, J |
| Detects | Piston magnet ring inside the cylinder |
2-wire versions run 10-28 V DC; NPN / PNP 3-wire versions run 5-30 V DC. IP64 as standard. Order the RW version where coolant, washdown or constant cable flexing is present. Switching distance, response time, current rating, voltage drop, LED behaviour, contact life, weight and dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| DMS | Electronic cylinder switch — electronic (solid-state). |
|---|---|
| G | Profile letter: the mounting / groove type that fits a particular cylinder body. This family offers E, G, H, J. It is a fit code, not a performance grade. |
| N | Output: NPN 3-wire. Blank is 2-wire, N is NPN 3-wire, P is PNP 3-wire. |
| 12 | See datasheet. 020 / 030 / 050 / 100 are 2 / 3 / 5 / 10 m flying leads; M08 and M12 are M8 / M12 connector versions. |
| (blank) | Standard version. |
We do not hold the full profile-to-cylinder-series table, so confirm the profile letter against your cylinder model before ordering — send us the cylinder part number and we will check the fit.
The split is electrical, not quality. Solid-state DMS and EMS are DC-only and suit modern PLC inputs; the reed-based CMS switches a much wider window, so it is the one for AC circuits, relay logic and older panels. The RW (IP68) option exists on DMS and EMS only.
| This switch | DMSG · NPN 3-wire · 5-30 V DC |
|---|---|
| Consider EMS | the mini 2-wire electronic switch for tight installations |
| Consider CMS | the reed alternative for AC circuits and voltages up to 240 V |
| Mounting parts | F-MQ (round body), F-ACT (tie-rod) |
Solid-state response without contact bounce suits a pick-and-place gantry where cylinders reverse direction dozens of times a minute.
Confirms a guard-locking cylinder has fully retracted before the controller allows the next cycle to start.
Position feedback lets a filling line controller verify each cylinder's home position after a format changeover.
Choose NPN 3-wire when your control system wants a crisp dedicated signal rather than a series-wired 2-wire loop; note that polarity matters, so NPN must match a sinking input. Before specifying the C12 termination into your drawing, request the datasheet from us - it is a coded variant, not a published connector type. If your cylinder groove matches G profile tooling and the piston carries the magnet, this switch completes the loop.
Quick checklist
Use the F-MQ bracket on round-body cylinders and F-ACT on tie-rod cylinders where there is no groove to seat the switch. Both are ordered separately from the switch. Switching distance and mounting dimensions come from the factory datasheet — ask us for the sheet that matches your cylinder.
Electronic (solid-state) switch, NPN 3-wire output, 5-30 V DC supply, IP64 protection. The wiring position carries the code C12, a connection code whose exact termination we will confirm from the datasheet.
Only 3-wire DMS switches offer the choice. NPN switches the load to the negative side and suits sinking PLC inputs; PNP switches the positive side for sourcing inputs. Pick the one that matches your input card or the signal will not read correctly.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, your cylinder model (so we can confirm the profile fit) and the destination. We confirm price, availability and lead time — usually within 7-8 hours.