The AirTAC Airtac DMSG Electronic Sensor DMSG-P050 is a genuine DMS magnetic position switch. It senses the magnet ring in a pneumatic cylinder's piston and signals when the piston reaches that point, giving a pnp 3-wire output on 5-30 V DC with a 5 m flying lead. It only works on a cylinder that carries a piston magnet.
The DMSG-P050 is a solid-state electronic position switch with a PNP 3-wire output. It clips into the sensor groove of an AirTAC cylinder fitted with the magnet option and signals when the piston reaches it. Supply is 5-30 V DC, protection is IP64, and the 5 m flying lead runs straight back to the control panel.
On a 3-wire PNP switch the supply and signal paths are separate, so a sinking PLC input receives a clean sourced pulse instead of the small standing leakage a 2-wire loop always leaves in circuit. That makes this version the usual pick for fast, repetitive indexing. The G in the code is a groove-fit code, not a grade - it must match the profile your cylinder body carries, so confirm the seat before you order.
| Model | Airtac DMSG Electronic Sensor DMSG-P050 |
|---|---|
| Family | DMS — Electronic cylinder switch |
| Technology | Electronic (solid-state) |
| Output | PNP 3-wire |
| Outputs in this family | 2-wire, NPN 3-wire or PNP 3-wire |
| Lead / connector | 5 m flying lead |
| Supply voltage | 5-30 V DC |
|---|---|
| Protection rating | IP64 |
| Version | Standard version |
| Profile letter | G (cylinder-groove fit) |
| Profiles in this family | E, G, H, J |
| Detects | Piston magnet ring inside the cylinder |
2-wire versions run 10-28 V DC; NPN / PNP 3-wire versions run 5-30 V DC. IP64 as standard. Order the RW version where coolant, washdown or constant cable flexing is present. Switching distance, response time, current rating, voltage drop, LED behaviour, contact life, weight and dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| DMS | Electronic cylinder switch — electronic (solid-state). |
|---|---|
| G | Profile letter: the mounting / groove type that fits a particular cylinder body. This family offers E, G, H, J. It is a fit code, not a performance grade. |
| P | Output: PNP 3-wire. Blank is 2-wire, N is NPN 3-wire, P is PNP 3-wire. |
| 050 | 5 m flying lead. 020 / 030 / 050 / 100 are 2 / 3 / 5 / 10 m flying leads; M08 and M12 are M8 / M12 connector versions. |
| (blank) | Standard version. |
We do not hold the full profile-to-cylinder-series table, so confirm the profile letter against your cylinder model before ordering — send us the cylinder part number and we will check the fit.
The split is electrical, not quality. Solid-state DMS and EMS are DC-only and suit modern PLC inputs; the reed-based CMS switches a much wider window, so it is the one for AC circuits, relay logic and older panels. The RW (IP68) option exists on DMS and EMS only.
| This switch | DMSG · PNP 3-wire · 5-30 V DC |
|---|---|
| Consider EMS | the mini 2-wire electronic switch for tight installations |
| Consider CMS | the reed alternative for AC circuits and voltages up to 240 V |
| Mounting parts | F-MQ (round body), F-ACT (tie-rod) |
Confirms full extension of pusher and cross-seal cylinders on a cartoning line, with the 5 m lead routed direct to the machine PLC's sinking input.
Mounted in the cylinder groove of a pick-and-place gripper, its PNP output gives the cell controller a positive part-present signal each cycle.
Tells the fixture controller on an assembly bench that pneumatic clamp cylinders have reached the locked position before the cycle is allowed to start.
Choose this model when your control system uses sinking inputs and you want the sharpest possible signal edge. Three wires keep power and switching apart, which suits counters, cam timing and any cycle where contact bounce would matter. If the panel sits further away, the DMSG-P100 with its 10 m lead, or an M8/M12 connector version, may serve better. The general IP64 body covers normal factory air; pick an -RW unit for washdown zones. A magnet-equipped cylinder (-S option) is required - the switch alone senses nothing - and the G profile must match the cylinder groove.
Quick checklist
Use the F-MQ bracket on round-body cylinders and F-ACT on tie-rod cylinders where there is no groove to seat the switch. Both are ordered separately from the switch. Switching distance and mounting dimensions come from the factory datasheet — ask us for the sheet that matches your cylinder.
It is an electronic (solid-state) switch with a PNP 3-wire output, supplied at 5-30 V DC, protected to IP64, and fitted with a 5 m flying lead. Current rating and other electrical limits: confirm from the datasheet.
A 2-wire switch wires in series like a mechanical contact, which is simple but leaves a small leakage current in the loop. A 3-wire PNP sources a clean signal into a sinking PLC input with no series leakage - the better choice for fast or count-critical cycles. PNP must match a sinking input card; NPN suits a sourcing card.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, your cylinder model (so we can confirm the profile fit) and the destination. We confirm price, availability and lead time — usually within 7-8 hours.