The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR200C08SJNK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR200C08SJNK is a filter and regulator combined into a single body, eliminating the need for separate components. It handles 1/4in ports and operates in the 0.15-0.9 MPa (20-130 psi) range with a 40 um element.
This unit features a metal bowl and a semi-auto plus manual drain. It weighs 290 g and its flow curve is plotted to 2000 L/min at 0.7 MPa inlet, providing a compact solution for basic pneumatic circuits.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR200C08SJNK |
|---|---|
| Series | GAFR200 filter & regulator |
| Port size | 1/4" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Bracket | Not included (J) |
| Weight | 290 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFR200 is 1/8" if you add one. This unit filters and regulates only; it does not add lubrication.
| GAFR200 | GA200 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 06 = 1/8", 08 = 1/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC200-08 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR200 · 1/4" · curve to 2000 L/min |
|---|---|
| One size up | GAFR300 (curve to 3500 L/min) |
| Add a lubricator | GAFC200-08 (F.R.L. combination) |
Feed a single pneumatic clamp or fixture on an assembly bench. The 1/4in port and 290 g weight suit compact, stationary tooling.
Supply clean, regulated air to a portable maintenance cart or small workbench setup. The metal bowl resists knocks in active workshop areas.
Provide stable pressure to a small laboratory instrument or test rig. The 40 um element filters particulates for sensitive equipment.
Choose this GAFR200 for small jigs or single actuators where space is tight and a 1/4in port is sufficient. The metal bowl suits demanding environments, while the semi-auto and manual drains offer flexible condensate removal. The J code means no bracket is included, and the N code means no gauge is fitted; the 1/8in gauge connection is available if you add one later. The K code indicates a reverse-flow (reflux) valve is fitted as an ordering difference. If you need lubrication downstream, order the matching GAFC200-08 combination instead. 1.0 MPa max supply leaves about 0.1 MPa above the 0.9 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC200-08 combination; do not expect an oil mist from this unit.
Working pressure is 0.15-0.9 MPa (20-130 psi), max pressure is 1.0 MPa (145 psi), proof pressure is 1.5 MPa (215 psi), temperature range is -5 to 70 C. The drain bowl holds 25 cc and the unit weighs 290 g.
The K code indicates a reverse-flow (reflux) valve is fitted. This is an ordering difference; the catalogue does not detail its function. The unit still has a semi-auto plus manual drain and a metal bowl.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.