The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR30010ASNK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR30010ASNK is a filter and regulator combined in a single body, so it cleans incoming air and sets a steady outlet pressure without needing separate units. This model uses a 3/8in port, a 40 um element, and a standard pressure range of 0.15-0.9 MPa (20-130 psi).
Its automatic drain clears condensate without manual attention, and the 60 cc bowl holds the collected water and solids. The pressed-in self-locking knob resists drift from vibration, keeping the set pressure stable during operation.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR30010ASNK |
|---|---|
| Series | GAFR300 filter & regulator |
| Port size | 3/8" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Bracket | Included |
| Weight | 500 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFR300 is 1/8" if you add one. This unit filters and regulates only; it does not add lubrication.
| GAFR300 | GA300 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Mounting bracket included. |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC300-10 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR300 · 3/8" · curve to 3500 L/min |
|---|---|
| One size down | GAFR200 |
| One size up | GAFR400 (curve to 7000 L/min) |
| Add a lubricator | GAFC300-10 (F.R.L. combination) |
Feed a single clamping fixture on a machining station where steady pressure is needed to hold parts consistently. The 40 um element protects the clamp valve from particles.
Supply a small test bench or analytical instrument that needs clean, regulated air. The automatic drain keeps the bowl from filling up during long experiments.
Power a pneumatic screwdriver or small actuator on an assembly line. The 3/8in port matches common tooling connections, and the 500 g body mounts easily on a rail.
Choose this GAFR300 if your line needs a 3/8in port and the 500 g body suits your mounting space. The PC bowl is the standard choice; if you need a different material, consider the C (metal) or N (nylon) versions. The automatic drain (A) is ideal for unattended or wet lines, while a blank drain code would give both semi-auto and manual drains. This unit includes the mounting bracket and has no gauge, so the 1/8in gauge connection is available if you add one later. The 40 um element handles general shop air, and the PT thread matches the MPa/psi gauge scale. The K code means a reverse-flow valve is fitted, which is an ordering difference to note. If your application needs lubrication downstream, order the matching GAFC300-10 combination instead. With a 1.0 MPa max supply, you have about 0.1 MPa above the 0.9 MPa top of the regulated range, so plan your inlet pressure near the maximum for full output.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC300-10 combination; do not expect an oil mist from this unit.
This filter & regulator has a 3/8in port, a pressure range of 0.15-0.9 MPa (20-130 psi), a max pressure of 1.0 MPa (145 psi), and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, has a 60 cc drain bowl, and weighs 500 g. The element is 40 um, and it has an automatic drain.
The K code indicates that a reverse-flow (reflux) valve is fitted to this unit. It is an ordering difference from models without the K code. The function of this valve is detailed in the catalogue on a page not included in our data, so we do not explain its operation here.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.