The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR300C08LJNWK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR300C08LJNWK is a filter and regulator combined into a single body, eliminating the need for separate GAF and GAR units. It delivers 1/4in porting with a lower-pressure range of 0.15-0.4 MPa (20-58 psi) and uses a 5 um element for fine particle removal.
This model features a metal bowl and a reverse-flow valve, with no gauge or bracket included. The diversion structure spins incoming air to separate liquid water and solid contaminants into the 60 cc drain bowl, while the balanced regulator maintains a steady outlet pressure as supply varies.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR300C08LJNWK |
|---|---|
| Series | GAFR300 filter & regulator |
| Port size | 1/4" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Bracket | Not included (J) |
| Weight | 500 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFR300 is 1/8" if you add one. This unit filters and regulates only; it does not add lubrication.
| GAFR300 | GA300 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC300-08 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR300 · 1/4" · curve to 3500 L/min |
|---|---|
| One size down | GAFR200 |
| One size up | GAFR400 (curve to 7000 L/min) |
| Add a lubricator | GAFC300-08 (F.R.L. combination) |
Feed a 5 um-filtered, low-pressure air supply to precision pneumatic valves on a small assembly station, where the lower 0.4 MPa ceiling protects delicate actuators.
Supply clean, regulated air to lab instruments that require fine filtration and a stable low pressure, with the metal bowl resisting accidental knocks.
Power a single clamping jig or small cylinder in a benchtop fixture, using the compact 500 g body with a manual drain for periodic maintenance.
Choose the GAFR300 body for 1/4in porting with a 3500 L/min flow envelope at 0.7 MPa inlet, a step down from the GAFR400's 7000 L/min envelope. The metal bowl suits demanding environments, while the 5 um element traps finer particles than the standard 40 um for sensitive equipment. This unit ships with both semi-auto and manual drains, and the L-type regulator caps at 0.4 MPa, so verify your system never needs more. The J code omits the bracket, and the N code means no gauge, leaving a 1/8in connection for future installation. The K code adds the reverse-flow valve as an ordering difference. For lines needing oil downstream, order the matching GAFC300-08 combination instead. With a 1.0 MPa max supply, you have about 0.6 MPa above the 0.4 MPa top of the regulated range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC300-08 combination; do not expect an oil mist from this unit.
This filter & regulator has a 1/4in port, a pressure range of 0.15-0.4 MPa (20-58 psi), a max pressure of 1.0 MPa (145 psi), and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, has a 60 cc drain bowl, and weighs 500 g.
The J code means no mounting bracket is included, and the N code means no gauge is fitted, leaving a 1/8in gauge connection. The L code sets a lower pressure range of 0.15-0.4 MPa instead of the standard 0.15-0.9 MPa.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.