The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR40010LJK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR40010LJK is a filter and regulator combined into a single body, so incoming air is cleaned and then set to a steady outlet pressure without needing separate units. This model uses a 3/8in port, a 40 um element, and a lower-pressure range of 0.15-0.4 MPa (20-58 psi), making it suitable for applications that need precise low-pressure control.
Its 100 cc condensate bowl and 880 g weight place it in the mid-size class, and the pressed-in self-locking knob resists set-pressure drift from vibration. The diversion structure spins the air to separate liquid water and solid particles into the bowl, protecting downstream equipment.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR40010LJK |
|---|---|
| Series | GAFR400 filter & regulator |
| Port size | 3/8" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Bracket | Not included (J) |
| Weight | 880 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code. This unit filters and regulates only; it does not add lubrication.
| GAFR400 | GA400 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC400-10 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR400 · 3/8" · curve to 7000 L/min |
|---|---|
| One size down | GAFR300 |
| One size up | GAFR500 (curve to 8000 L/min) |
| Add a lubricator | GAFC400-10 (F.R.L. combination) |
Feed a delicate clamping jig that requires a stable 0.3 MPa supply, where the lower-pressure range prevents accidental over-pressurization of sensitive fixtures.
Supply instrument air to a lab bench with a 3/8in line, using the 40 um filter to protect analytical devices from particulates and the regulator to hold a gentle pressure.
Mount this unit inside a control cabinet where the missing bracket allows direct panel installation, and the compact 880 g body fits without stressing the enclosure.
Choose this GAFR400 body when you need a 3/8in port and a 100 cc drain bowl, stepping up from the GAFR300's 60 cc bowl for longer intervals between draining. The L type limits the regulated range to 0.15-0.4 MPa (20-58 psi), so confirm your system never needs more than that; the J code means no mounting bracket is included, so plan for a panel mount or existing bracket. The PC bowl is the standard build, the semi-auto plus manual drain covers both automatic and manual draining, and the gauge is fitted with an MPa/psi scale on the PT thread. The K code adds the reverse-flow valve, which is an ordering difference to note. If your line needs oil downstream, order the matching GAFC400-10 combination instead. 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC400-10 combination; do not expect an oil mist from this unit.
The GAFR40010LJK is a filter & regulator with a 3/8in port, a 40 um element, and a lower-pressure range of 0.15-0.4 MPa (20-58 psi). Maximum pressure is 1.0 MPa (145 psi), proof pressure is 1.5 MPa (215 psi), and the temperature range is -5 to 70 C. It has a 100 cc drain bowl and weighs 880 g.
The K code indicates that a reverse-flow (reflux) valve is fitted to this unit. It is an ordering difference that adds the valve to the assembly; the catalogue defers its function to another page, so it is listed here as a configuration option.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.