The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR400C10ALN is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR400C10ALN is a genuine AirTAC filter and regulator combined into one body, with no lubricator section. It spins incoming air to separate liquid water and solid particles, then delivers a steady outlet pressure through a balanced regulator mechanism. This model uses a 3/8in port, a 100 cc metal condensate bowl, and a 40 um filter element.
Its lower-pressure type regulates from 0.15 to 0.4 MPa (20-58 psi), making it suitable for gentle or sensitive applications. The pressed-in self-locking knob resists drift from vibration, helping maintain the set pressure. At 880 g, this unit needs proper panel or frame mounting rather than support from the tubing.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR400C10ALN |
|---|---|
| Series | GAFR400 filter & regulator |
| Port size | 3/8" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Bracket | Included |
| Weight | 880 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFR400 is 1/4" if you add one. This unit filters and regulates only; it does not add lubrication.
| GAFR400 | GA400 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Mounting bracket included. |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC400-10 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR400 · 3/8" · curve to 7000 L/min |
|---|---|
| One size down | GAFR300 |
| One size up | GAFR500 (curve to 8000 L/min) |
| Add a lubricator | GAFC400-10 (F.R.L. combination) |
Use the lower-pressure range to set a delicate 0.3 MPa supply for a small pneumatic clamp or a sensitive test fixture, where a standard regulator might deliver too much force.
The automatic drain removes condensate without manual checks, making this unit a fit for a compressor room or a humid plant area where water accumulates quickly in the 100 cc bowl.
Mount this 880 g filter-regulator on a machine frame or control panel using the included bracket, feeding a single 3/8in line to a local actuator or a small valve manifold.
Choose the GAFR400 body for a 3/8in port with a 100 cc drain bowl and a flow curve plotted to 7000 L/min at 0.7 MPa inlet. The metal bowl (C) suits demanding environments; confirm compatibility for aggressive surroundings. The automatic drain (A) handles wet or unattended lines, while the included bracket simplifies mounting. The L type tops out at 0.4 MPa, so verify your supply stays within this band. No gauge is fitted, but the 1/4in gauge connection allows adding one later. The 40 um element handles standard shop air; the W option upgrades to 5 um. PT threads pair with an MPa/psi gauge scale. If oil is needed downstream, order the matching GAFC400-10 combination instead. A 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC400-10 combination; do not expect an oil mist from this unit.
This is a filter and regulator in one body. The pressure range is 0.15-0.4 MPa (20-58 psi), with a maximum supply of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C and must not freeze. The drain bowl holds 100 cc, and the unit weighs 880 g. It has a 3/8in port, a 40 um element, and an automatic drain.
The L code sets the regulated range to 0.15-0.4 MPa, which is about 44% of the standard type's ceiling, for applications that need gentle pressure. The N code means no gauge is supplied; the 1/4in gauge connection is there if you add one later. This model also has a metal bowl and an automatic drain.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.