The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR400C10LJK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR400C10LJK is a filter and pressure regulator combined in a single body, eliminating the need for separate GAF and GAR units. It spins incoming air to separate liquid water and trap solid particles, then delivers a steady outlet pressure through a balanced mechanism; the pressed-in self-locking knob resists drift from vibration.
This model has a 3/8" port, a lower-pressure range of 0.15-0.4 MPa (20-58 psi), and a 40 um element. The metal bowl holds 100 cc of condensate, and the unit weighs 880 g, placing it in the GAFR400 size class that suits medium-flow machine circuits.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR400C10LJK |
|---|---|
| Series | GAFR400 filter & regulator |
| Port size | 3/8" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Bracket | Not included (J) |
| Weight | 880 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code. This unit filters and regulates only; it does not add lubrication.
| GAFR400 | GA400 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC400-10 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR400 · 3/8" · curve to 7000 L/min |
|---|---|
| One size down | GAFR300 |
| One size up | GAFR500 (curve to 8000 L/min) |
| Add a lubricator | GAFC400-10 (F.R.L. combination) |
Feed a bank of precision pneumatic valves on a pick-and-place machine where the lower 0.4 MPa ceiling prevents over-pressuring sensitive actuators.
Protect a machining center's pneumatic clamping circuit from water and particulates, with the metal bowl handling shop-floor conditions.
Supply a lab test fixture with clean, regulated air at a stable low pressure, using the 100 cc bowl to extend time between manual drains.
Choose the GAFR400 body for lines needing up to 7000 L/min plotted flow at 0.7 MPa inlet, a step up from the GAFR300's 3500 L/min envelope. The metal bowl (C) is a build choice for the environment; the semi-auto plus manual drain requires an operator to check the 100 cc bowl, while an A code would automate that task. The L type tops out at 0.4 MPa, so verify the machine never needs more; the J code means no bracket is included, and the fitted gauge reads MPa/psi on PT threads. The K code adds a reverse-flow (reflux) valve as an ordering difference. If oil is needed downstream, order the matching GAFC400-10 combination instead. For this unit, 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC400-10 combination; do not expect an oil mist from this unit.
Pressure range is 0.15-0.4 MPa (20-58 psi), max pressure 1.0 MPa (145 psi), proof pressure 1.5 MPa (215 psi), temperature -5 to 70 C. The drain bowl holds 100 cc, the unit weighs 880 g, and the port is 3/8".
The K code indicates a reverse-flow (reflux) valve is fitted. It is an ordering difference from the standard version; the catalogue defers its function to a separate page, so no operational details are provided here.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.