The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR400C10LNWK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR400C10LNWK is a filter and regulator combined in one body, cleaning incoming air and setting a steady outlet pressure without any lubricator. This 3/8in unit operates in the lower 0.15-0.4 MPa (20-58 psi) band and uses a 5 um element to trap fine particles.
Its metal bowl holds 100 cc of condensate, and the 880 g body includes a mounting bracket. A reverse-flow valve is fitted, and the unit has no gauge, so the 1/4in gauge connection is available if you add one later.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR400C10LNWK |
|---|---|
| Series | GAFR400 filter & regulator |
| Port size | 3/8" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Bracket | Included |
| Weight | 880 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFR400 is 1/4" if you add one. This unit filters and regulates only; it does not add lubrication.
| GAFR400 | GA400 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Mounting bracket included. |
| N | No pressure gauge; 1/4" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC400-10 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR400 · 3/8" · curve to 7000 L/min |
|---|---|
| One size down | GAFR300 |
| One size up | GAFR500 (curve to 8000 L/min) |
| Add a lubricator | GAFC400-10 (F.R.L. combination) |
Feed a 3/8in line to a precision assembly station where lower pressure protects delicate grippers and the 5 um element keeps fine particles away from sensitive valves.
Use in a lab setting where the lower pressure range and fine filtration suit test fixtures that need clean, regulated air without the risk of over-pressurizing.
Mount on light machine tools that run at lower pressures, where the metal bowl resists shop-floor impacts and the 100 cc bowl handles moderate condensate.
Choose this GAFR400 for a 3/8in line where the lower pressure range suits delicate equipment. The metal bowl suits industrial environments, while the 5 um element filters finer solids than the standard 40 um grade. This model includes the mounting bracket, has a semi-auto plus manual drain, and comes without a gauge. The PT thread matches standard local fittings, and the reflux valve is an ordering difference you should confirm for your circuit. If you need oil downstream, order the matching GAFC400-10 combination instead. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa regulated ceiling.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC400-10 combination; do not expect an oil mist from this unit.
The GAFR400C10LNWK operates from 0.15 to 0.4 MPa (20-58 psi), with a maximum pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It works in temperatures from -5 to 70 C, has a 100 cc drain bowl, and weighs 880 g.
The N code means no gauge is supplied, so you cannot read the set pressure without adding one to the 1/4in connection. The K code indicates a reverse-flow (reflux) valve is fitted; its function is detailed in the catalogue, but it is an ordering difference you should confirm for your application.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.