The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR400C15ALJ is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR400C15ALJ is a filter & regulator with both functions in one body: it spins incoming air to separate liquid water and solid particles, then delivers a steady outlet pressure through a balanced, self-locking regulator. This 1/2in unit carries a metal bowl and a 100 cc condensate chamber, weighing 880 g.
Its lower-pressure type regulates from 0.15 to 0.4 MPa (20-58 psi), with a 40 um element for standard filtration. The automatic drain clears condensate without manual attention, and the circular gauge with MPa/psi scale is fitted. No lubricator is present; if oil is needed downstream, the matching GAFC400-15 combination adds that function.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR400C15ALJ |
|---|---|
| Series | GAFR400 filter & regulator |
| Port size | 1/2" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Bracket | Not included (J) |
| Weight | 880 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code. This unit filters and regulates only; it does not add lubrication.
| GAFR400 | GA400 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC400-15 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR400 · 1/2" · curve to 7000 L/min |
|---|---|
| One size down | GAFR300 |
| One size up | GAFR500 (curve to 8000 L/min) |
| Add a lubricator | GAFC400-15 (F.R.L. combination) |
Feed a calibrated pneumatic press or a precision clamping fixture that requires a stable, lower regulated pressure. The balanced regulator holds the setpoint as supply varies, and the 40 um element protects sensitive valves downstream.
Supply a consistent 0.15-0.4 MPa to coolant misters or air blow-off nozzles on a machining center. The automatic drain handles condensate from wet shop air, and the metal bowl suits demanding plant environments.
Use in a lab or quality bench where a clean, regulated air source at lower pressure is needed for leak testing or calibration. The 100 cc bowl reduces drain frequency, and the gauge gives a clear local readout.
Choose this GAFR400 when you need a 1/2in port with a 100 cc metal bowl and automatic drain. The lower-pressure type tops out at 0.4 MPa, so confirm your system never requires more than that. The J code means no mounting bracket is included, and the PT thread brings an MPa/psi gauge scale. For finer filtration, select the W option for a 5 um element. If the line needs lubrication, order the GAFC400-15 combination instead. The 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC400-15 combination; do not expect an oil mist from this unit.
Working pressure range is 0.15-0.4 MPa (20-58 psi). Maximum pressure is 1.0 MPa (145 psi) and proof pressure is 1.5 MPa (215 psi). Temperature range is -5 to 70 C. The drain bowl holds 100 cc and the unit weighs 880 g. It has a 1/2in port, 40 um element, metal bowl, and automatic drain.
The L code sets the regulated range to 0.15-0.4 MPa, suitable for applications needing a lower, stable pressure. The J code omits the mounting bracket, so you must provide your own panel mount or existing bracket. The automatic drain (A) clears condensate without manual intervention.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.