The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR400C15ASJNWK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR400C15ASJNWK is a filter and pressure regulator combined in one body, eliminating the need for separate GAF and GAR units. This 1/2in port model with a metal bowl weighs 880 g and filters down to 5 um while regulating pressure from 0.15-0.9 MPa (20-130 psi).
The diversion structure spins incoming air to separate liquid water and solid particles into the 100 cc drain bowl. The balanced, self-locking regulator holds the outlet steady as supply pressure varies, and the pressed-in knob resists drift from vibration.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR400C15ASJNWK |
|---|---|
| Series | GAFR400 filter & regulator |
| Port size | 1/2" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Bracket | Not included (J) |
| Weight | 880 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFR400 is 1/4" if you add one. This unit filters and regulates only; it does not add lubrication.
| GAFR400 | GA400 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| N | No pressure gauge; 1/4" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC400-15 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR400 · 1/2" · curve to 7000 L/min |
|---|---|
| One size down | GAFR300 |
| One size up | GAFR500 (curve to 8000 L/min) |
| Add a lubricator | GAFC400-15 (F.R.L. combination) |
Feed a 1/2in line to CNC machine coolant valves where the 5 um element protects precision solenoids from fine abrasive dust.
Supply a multi-station assembly bench with regulated air, using the automatic drain to handle condensate from a wet compressor line.
Provide stable 0.15-0.9 MPa air to pneumatic test fixtures where the metal bowl resists rough handling and the reflux valve is specified.
Choose this GAFR400 body for 1/2in port lines needing up to 7000 L/min flow (plotted at 0.7 MPa inlet). The metal bowl suits demanding environments, while the automatic drain handles unattended operation. This model omits the bracket (J) and gauge (N), so plan for panel mounting and use the 1/4in gauge connection if you add one later. The 5 um element traps finer particles than standard 40 um, and the reverse-flow valve is fitted. If oil is needed downstream, order the GAFC400-15 combination instead. Note that 1.0 MPa max supply leaves about 0.1 MPa above the 0.9 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC400-15 combination; do not expect an oil mist from this unit.
Working pressure is 0.15-0.9 MPa (20-130 psi), max pressure 1.0 MPa (145 psi), proof pressure 1.5 MPa (215 psi), temperature range -5 to 70 C. The drain bowl holds 100 cc and the unit weighs 880 g with a 1/2in port.
The N code means no gauge is supplied, but the 1/4in gauge connection is ready for a field-installed unit. The J code omits the mounting bracket for installations using existing panel mounts or custom frames.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.