The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR400C15ASWK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR400C15ASWK is a filter and regulator combined into one body, so a single unit handles both air preparation and pressure control. It has a 1/2in port, a 0.15-0.9 MPa (20-130 psi) working range, and a 5 um element that traps fine particles for sensitive equipment.
This model uses a metal bowl and an automatic drain, making it suited for continuous operation where manual draining is impractical. The 100 cc condensate bowl and 880 g weight define its size class, and the included mounting bracket provides secure installation for a unit of this mass.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR400C15ASWK |
|---|---|
| Series | GAFR400 filter & regulator |
| Port size | 1/2" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Bracket | Included |
| Weight | 880 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code. This unit filters and regulates only; it does not add lubrication.
| GAFR400 | GA400 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Mounting bracket included. |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC400-15 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR400 · 1/2" · curve to 7000 L/min |
|---|---|
| One size down | GAFR300 |
| One size up | GAFR500 (curve to 8000 L/min) |
| Add a lubricator | GAFC400-15 (F.R.L. combination) |
Feed a bank of precision pneumatic valves that need clean, regulated air at a steady pressure. The 5 um element removes fine particulates that could clog small orifices.
Supply a machining center's pneumatic clamping system with filtered air at a consistent 0.15-0.9 MPa. The automatic drain keeps the metal bowl from filling during long production runs.
Protect actuators on an assembly line from water and solids while maintaining set pressure. The 100 cc bowl and 7000 L/min envelope at 0.7 MPa inlet support multiple devices.
Choose the GAFR400 body when you need a 1/2in port and a flow envelope plotted to 7000 L/min at 0.7 MPa inlet, which is double the GAFR300's 3500 L/min envelope. The metal bowl is a build choice for demanding environments, while the standard S type covers 0.15-0.9 MPa (20-130 psi) for most applications. The automatic drain handles condensate without attention, and the 5 um element suits precision valves but requires more frequent service than a 40 um unit. The included bracket simplifies mounting, and the fitted gauge reads in MPa/psi. The K code adds a reverse-flow (reflux) valve as an ordering difference. If the line needs oil downstream, order the matching GAFC400-15 combination instead. Note that 1.0 MPa max supply leaves about 0.1 MPa above the 0.9 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC400-15 combination; do not expect an oil mist from this unit.
Working pressure is 0.15-0.9 MPa (20-130 psi), with a 1.0 MPa (145 psi) maximum and 1.5 MPa (215 psi) proof pressure. Temperature range is -5 to 70 C. The drain bowl holds 100 cc and the unit weighs 880 g. It has a 1/2in port and a 5 um filter element.
The K indicates a reverse-flow (reflux) valve is fitted. This is an ordering difference from a standard GAFR400; the catalogue details its function separately. This unit remains a filter and regulator only, with no lubricator.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.