The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR400C15LJNK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR400C15LJNK is a filter and regulator combined into a single body, eliminating the need for separate GAF filter and GAR regulator units. This 1/2in port model weighs 880 g and filters incoming air to 40 um while regulating outlet pressure from 0.15 to 0.4 MPa (20-58 psi).
Its metal bowl collects condensate and solids separated by the diversion structure, holding up to 100 cc before draining. The unit comes without a gauge, so the 1/4in gauge connection remains available for adding one later.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR400C15LJNK |
|---|---|
| Series | GAFR400 filter & regulator |
| Port size | 1/2" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Bracket | Not included (J) |
| Weight | 880 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFR400 is 1/4" if you add one. This unit filters and regulates only; it does not add lubrication.
| GAFR400 | GA400 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC400-15 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR400 · 1/2" · curve to 7000 L/min |
|---|---|
| One size down | GAFR300 |
| One size up | GAFR500 (curve to 8000 L/min) |
| Add a lubricator | GAFC400-15 (F.R.L. combination) |
Set a stable 0.3 MPa supply for a precision pneumatic vise or a delicate assembly fixture that must not see higher pressure.
Feed a 1/2in header serving coolant valves and small cylinders where a lower pressure limit protects downstream components.
Provide filtered air at a controlled low pressure for leak testing or calibration setups that require a gentle, consistent flow.
Choose this GAFR400 for 1/2in piping where a lower regulated pressure band of 0.15-0.4 MPa (20-58 psi) is sufficient. The metal bowl suits demanding environments, while the semi-auto and manual drains require periodic attention. No bracket is included, so plan for panel mounting or an existing support. The 40 um element handles general shop air, and the PT threads match standard local fittings. The reverse-flow valve is fitted as an ordering option. If lubrication is needed downstream, order the matching GAFC400-15 combination instead. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa top of the regulated range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC400-15 combination; do not expect an oil mist from this unit.
It operates from 0.15 to 0.4 MPa (20-58 psi) with a maximum supply of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Temperature range is -5 to 70 C. The metal drain bowl holds 100 cc and the unit weighs 880 g.
The N code after the port means no gauge is supplied; the 1/4in gauge connection is there if you add one later. The J code means the mounting bracket is omitted, so you must use an existing bracket or panel mount.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.