The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR400C15SJN is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR400C15SJN is a filter & regulator in one body: it spins incoming air to separate liquid water and trap solid particles, then a balanced regulator holds a steady outlet pressure as supply varies. This 1/2in unit works in the 0.15-0.9 MPa (20-130 psi) range with a 40 um element, and has no lubricator - it only filters and regulates.
Its metal bowl holds 100 cc of condensate, and the 880 g body needs a proper panel or frame mount rather than support from the tubing. The pressed-in self-locking knob resists set-pressure drift from vibration, keeping the outlet stable in industrial environments.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR400C15SJN |
|---|---|
| Series | GAFR400 filter & regulator |
| Port size | 1/2" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Bracket | Not included (J) |
| Weight | 880 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFR400 is 1/4" if you add one. This unit filters and regulates only; it does not add lubrication.
| GAFR400 | GA400 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC400-15 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR400 · 1/2" · curve to 7000 L/min |
|---|---|
| One size down | GAFR300 |
| One size up | GAFR500 (curve to 8000 L/min) |
| Add a lubricator | GAFC400-15 (F.R.L. combination) |
Feed a 1/2in line to a CNC machine's clamping system, where the 40 um element protects solenoid valves and the stable regulated pressure keeps clamping force consistent.
Mount this GAFR400 on a multi-station assembly bench to supply filtered air at a set pressure to multiple pneumatic tools, with the 100 cc bowl reducing drain frequency during shifts.
Use it on a test bench where you need clean, regulated air at a known pressure for fixture actuation, relying on the balanced regulator to hold the setpoint as shop pressure fluctuates.
Choose the GAFR400 body for 1/2in ports and a 100 cc drain bowl, stepping up from the GAFR300's 60 cc bowl when you need longer intervals between draining. The metal bowl (C) suits demanding build environments, while the semi-auto plus manual drain gives you both automatic purging and a manual override. This J model omits the mounting bracket for panel-mount installations, and the N code means no gauge is supplied - the 1/4in gauge connection is ready if you add one later. The standard S type covers 0.15-0.9 MPa, and the 40 um element handles general shop air; choose the W option for 5 um filtration if you feed precision valves. With a 1.0 MPa max supply, you have about 0.1 MPa above the 0.9 MPa top of the regulated range, so plan your inlet pressure near 1.0 MPa for full output.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC400-15 combination; do not expect an oil mist from this unit.
This filter & regulator has a 1/2in port, working pressure range of 0.15-0.9 MPa (20-130 psi), max pressure of 1.0 MPa (145 psi), proof pressure of 1.5 MPa (215 psi), and operates from -5 to 70 C. The metal drain bowl holds 100 cc, the unit weighs 880 g, and it uses a 40 um element with a 1/4in gauge connection.
The N code after the port means no gauge is fitted - you can add one later via the 1/4in connection if you need to read the set pressure. The J code omits the mounting bracket, which suits panel-mount installations or setups that already have a bracket in place. Both options reduce initial cost when you don't need those components.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.