The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR400N15LNWK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR400N15LNWK is a filter & regulator with both functions in one body: it spins incoming air to separate liquid water and solid particles, then a balanced regulator holds a steady outlet pressure. This model has a 1/2in port, a 0.15-0.4 MPa (20-58 psi) lower-pressure range, and a 5 um element for finer filtration.
The nylon bowl holds 100 cc of condensate, and the unit weighs 880 g. It ships with a mounting bracket and a semi-auto plus manual drain. A reverse-flow (reflux) valve is fitted as an ordering difference, and no gauge is supplied; the 1/4in gauge connection is available if one is added later.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR400N15LNWK |
|---|---|
| Series | GAFR400 filter & regulator |
| Port size | 1/2" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Bracket | Included |
| Weight | 880 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFR400 is 1/4" if you add one. This unit filters and regulates only; it does not add lubrication.
| GAFR400 | GA400 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Mounting bracket included. |
| N | No pressure gauge; 1/4" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC400-15 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR400 · 1/2" · curve to 7000 L/min |
|---|---|
| One size down | GAFR300 |
| One size up | GAFR500 (curve to 8000 L/min) |
| Add a lubricator | GAFC400-15 (F.R.L. combination) |
Feed a bank of precision pneumatic valves on a 1/2in manifold. The 5 um element traps fine particles that could clog small orifices, and the lower-pressure range suits delicate actuation.
Supply a single machine tool's air header with a steady 0.15-0.4 MPa output. The 100 cc bowl handles condensate from a moderately wet line, and the included bracket mounts firmly to the frame.
Use on a lab or test rig where low, stable pressure is required. The semi-auto plus manual drain lets an operator clear the bowl on schedule, and the 880 g mass needs a proper panel mount.
Choose the GAFR400 body for a 1/2in port with a 100 cc drain bowl and a flow envelope plotted to 7000 L/min at 0.7 MPa inlet. The nylon bowl is a build choice; the common 1.0 MPa max and -5 to 70 C rating apply to all bowl materials, so confirm compatibility for aggressive surroundings. This unit has a semi-auto plus manual drain, a 5 um element, and the mounting bracket included; the L type tops out at 0.4 MPa, so if the machine may ever need more, the standard S type is the right part. The K code adds a reverse-flow (reflux) valve, and the PT thread sets the gauge scale to MPa/psi. If oil is needed downstream, order the matching GAFC400-15 combination instead. 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC400-15 combination; do not expect an oil mist from this unit.
The GAFR400N15LNWK is a filter & regulator with a 1/2in port, a lower-pressure range of 0.15-0.4 MPa (20-58 psi), a max pressure of 1.0 MPa (145 psi), and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, has a 100 cc drain bowl, and weighs 880 g. The element is 5 um, and the drain is semi-auto plus manual.
The K code indicates the reverse-flow (reflux) valve is fitted as an ordering difference. The catalogue defers its function to a separate page, so this is noted as a build option only. If you need lubrication downstream, the matching GAFC400-15 combination adds a lubricator; this GAFR unit does not.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.