The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR400N15SJNK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR400N15SJNK is a filter and pressure regulator combined into a single body, saving rail space and reducing potential leak points compared to separate units. It handles 1/2in ports and delivers a standard pressure range of 0.15-0.9 MPa (20-130 psi) with a 40 um filtering element.
This version features a nylon bowl and comes without a mounting bracket or gauge, but includes a reverse-flow valve. The diversion structure spins incoming air to separate liquid water and solid particles into the 100 cc drain bowl, while the balanced, self-locking regulator maintains a steady outlet pressure despite supply fluctuations.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR400N15SJNK |
|---|---|
| Series | GAFR400 filter & regulator |
| Port size | 1/2" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Bracket | Not included (J) |
| Weight | 880 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFR400 is 1/4" if you add one. This unit filters and regulates only; it does not add lubrication.
| GAFR400 | GA400 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC400-15 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR400 · 1/2" · curve to 7000 L/min |
|---|---|
| One size down | GAFR300 |
| One size up | GAFR500 (curve to 8000 L/min) |
| Add a lubricator | GAFC400-15 (F.R.L. combination) |
Feed a multi-axis clamping fixture on a CNC mill where the 1/2in port and 7000 L/min flow envelope (at 0.7 MPa inlet) support multiple pneumatic cylinders. The 100 cc bowl handles condensate from a moderately wet shop line.
Supply a small sub-manifold feeding three or four pick-and-place actuators on an assembly line. The self-locking regulator keeps set pressure stable despite vibration from adjacent stamping equipment.
Provide clean, regulated air to a functional test bench for valves or fittings. The 40 um element protects sensitive test instrumentation, and the manual drain allows quick purging between shifts.
Choose this GAFR400 for medium-flow applications needing 1/2in ports and a 100 cc condensate bowl, which holds about 1.7x the volume of a GAFR300's 60 cc bowl for less frequent draining. The nylon bowl offers a different build option compared to PC or metal, though all share the same 1.0 MPa (145 psi) maximum pressure rating. This model has a semi-auto drain plus manual drain, no bracket (J), no gauge (N), and a 40 um element; the gauge connection is 1/4in if you add one later. The reverse-flow valve (K) is fitted as an ordering difference, and the PT thread uses an MPa/psi gauge scale. If your line needs oil downstream, order the matching GAFC400-15 combination instead. 1.0 MPa max supply leaves about 0.1 MPa above the 0.9 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC400-15 combination; do not expect an oil mist from this unit.
The GAFR400N15SJNK operates from 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Temperature range is -5 to 70 C. It has a 100 cc drain bowl and weighs 880 g. The port size is 1/2in and the filtering grade is 40 um.
The 'N' after the port code means no gauge is supplied, leaving a 1/4in gauge connection for adding one later. The 'J' means the mounting bracket is omitted, making this suitable for panel-mount installations or when using an existing bracket. Both options reduce cost when these features are not needed.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.