The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR50020ASJNW is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 3/4" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR50020ASJNW is a filter and regulator combined into a single body, eliminating the need for separate filter and regulator units. This 3/4in model handles supply pressures from 0.15-0.9 MPa (20-130 psi) and uses a 5 um element for fine particle removal.
A diversion structure spins incoming air to separate liquid water and solid debris into the 108 cc condensate bowl. The balanced regulator mechanism maintains a steady outlet pressure as inlet pressure fluctuates, while the pressed-in self-locking knob prevents set-point drift from vibration.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR50020ASJNW |
|---|---|
| Series | GAFR500 filter & regulator |
| Port size | 3/4" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 108 cc |
| Bracket | Not included (J) |
| Weight | 950 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFR500 is 1/4" if you add one. This unit filters and regulates only; it does not add lubrication.
| GAFR500 | GA500 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 20 | Port size 3/4". This body offers 20 = 3/4". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| N | No pressure gauge; 1/4" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC500-20 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR500 · 3/4" · curve to 8000 L/min |
|---|---|
| One size down | GAFR400 |
| One size up | GAFR600 (curve to 12000 L/min) |
| Add a lubricator | GAFC500-20 (F.R.L. combination) |
Feed a multi-station assembly machine header with clean, regulated air at 3/4in port capacity.
Use the 5 um element to protect sensitive pneumatic valves and positioners from fine particulate.
Supply steady pressure to conveyor diverters and stops where automatic draining prevents water buildup.
This GAFR500 body suits high-flow applications with its 3/4in port and 950 g mass, demanding proper panel or frame mounting rather than tubing support. The automatic drain (A) handles unattended operation or wet lines, while the 5 um element (W) traps finer particles than the standard 40 um for precision equipment. No bracket (J) is included for panel-mount installations, and no gauge (N) is supplied - the 1/4in gauge connection allows adding one later. The PT thread uses an MPa/psi scale. If oil is needed downstream, order the matching GAFC500-20 combination instead.
1.0 MPa max supply leaves about 0.1 MPa above the 0.9 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC500-20 combination; do not expect an oil mist from this unit.
Working pressure range is 0.15-0.9 MPa (20-130 psi), max pressure 1.0 MPa (145 psi), proof pressure 1.5 MPa (215 psi), temperature range -5 to 70 C. The drain bowl holds 108 cc and the unit weighs 950 g.
The N code means no gauge is supplied, though the 1/4in gauge connection allows adding one later. The J code omits the mounting bracket for installations using existing brackets or panel mounts. Both options reduce cost when standard accessories are unnecessary.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.