The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR500C20SJNK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 3/4" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR500C20SJNK is a filter and regulator combined into a single body, handling both air preparation duties without the need for separate units. It serves a 3/4in line with a standard pressure range of 0.15-0.9 MPa (20-130 psi) and a 40 um filtering element.
This metal-bowl version weighs 950 g and uses a diversion structure to spin out liquid water and solid particles into its 108 cc condensate bowl. The balanced, self-locking regulator keeps the outlet pressure steady as supply varies, and the pressed-in knob resists drift from vibration.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR500C20SJNK |
|---|---|
| Series | GAFR500 filter & regulator |
| Port size | 3/4" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 108 cc |
| Bracket | Not included (J) |
| Weight | 950 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFR500 is 1/4" if you add one. This unit filters and regulates only; it does not add lubrication.
| GAFR500 | GA500 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 20 | Port size 3/4". This body offers 20 = 3/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC500-20 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR500 · 3/4" · curve to 8000 L/min |
|---|---|
| One size down | GAFR400 |
| One size up | GAFR600 (curve to 12000 L/min) |
| Add a lubricator | GAFC500-20 (F.R.L. combination) |
Feed a multi-station machine header where a single 3/4in line supplies several actuators. The 108 cc bowl and 950 g body handle the condensate load of continuous operation.
Mount in a process control panel to protect downstream valves and positioners. The 40 um element traps particles that could clog fine orifices in precision equipment.
Install at an assembly line drop for tools and fixtures. The semi-auto drain purges water automatically while the manual backup gives operators control during maintenance.
Choose the GAFR500 when your line needs 3/4in ports and a flow envelope plotted to 8000 L/min at 0.7 MPa inlet. The metal bowl suits demanding environments, while the semi-auto+manual drain gives you both automatic purging and manual control. This model has no mounting bracket (J) and no gauge (N), so plan for a panel mount and use the 1/4in gauge connection if you add one later. The 40 um element handles standard shop air, and the PT thread matches common local fittings. The reverse-flow (reflux) valve is fitted as an ordering difference. If you need lubrication downstream, order the matching GAFC500-20 combination instead. 1.0 MPa max supply leaves about 0.1 MPa above the 0.9 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC500-20 combination; do not expect an oil mist from this unit.
Working pressure is 0.15-0.9 MPa (20-130 psi), max pressure is 1.0 MPa (145 psi), proof pressure is 1.5 MPa (215 psi), and temperature range is -5 to 70 C. It has a 108 cc drain bowl, weighs 950 g, and uses a 40 um element.
The N code means no gauge is supplied, so you cannot read the set pressure without adding one to the 1/4in gauge connection. The J code omits the mounting bracket, which suits panel-mount installations or setups that reuse existing brackets.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.