The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR500N20LJ is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 3/4" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR500N20LJ is a filter & regulator that combines air filtration and pressure regulation in a single body, eliminating the need for separate GAF and GAR units. This 3/4in model operates in the lower pressure band of 0.15-0.4 MPa (20-58 psi) and comes with a 40 um element.
Its nylon bowl and 108 cc condensate capacity suit applications where weight reduction matters, while the diversion structure spins air to separate liquid water and solid particles. The pressed-in self-locking knob resists set-pressure drift from vibration, keeping the outlet steady as supply pressure varies.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR500N20LJ |
|---|---|
| Series | GAFR500 filter & regulator |
| Port size | 3/4" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 108 cc |
| Bracket | Not included (J) |
| Weight | 950 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code. This unit filters and regulates only; it does not add lubrication.
| GAFR500 | GA500 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 20 | Port size 3/4". This body offers 20 = 3/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC500-20 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR500 · 3/4" · curve to 8000 L/min |
|---|---|
| One size down | GAFR400 |
| One size up | GAFR600 (curve to 12000 L/min) |
| Add a lubricator | GAFC500-20 (F.R.L. combination) |
Feed a bank of precision pneumatic valves that require a stable, lower regulated pressure below 0.4 MPa. The balanced regulator holds the setpoint as supply fluctuates.
Maintain consistent air pressure for conveyor belt tensioning cylinders in a packaging line. The 3/4in port delivers adequate flow while the 108 cc bowl handles condensate between shifts.
Supply filtered air to a machine tool's coolant system where a lower pressure prevents over-spray. The self-locking knob keeps the setting stable despite machine vibration.
Choose the GAFR500N20LJ when your line needs 3/4in ports and a regulated output capped at 0.4 MPa. The nylon bowl (N) offers a lighter alternative to metal, and the semi-auto plus manual drain gives you both automatic condensate release and a manual override. This model ships without the mounting bracket (J), so plan for panel mounting or an existing bracket solution.
The 40 um element handles general shop air, and the fitted circular gauge reads in MPa/psi. If your machine may ever require more than 0.4 MPa, select the standard S type instead, since 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC500-20 combination; do not expect an oil mist from this unit.
Working pressure range is 0.15-0.4 MPa (20-58 psi), max pressure is 1.0 MPa (145 psi), proof pressure is 1.5 MPa (215 psi), temperature range is -5 to 70 C. The drain bowl holds 108 cc and the unit weighs 950 g. It has a 3/4in port, 40 um element, and a fitted gauge reading MPa/psi.
The L code sets the lower pressure range (0.15-0.4 MPa) for applications needing gentle, stable pressure. The J code omits the mounting bracket, so you must use an existing bracket or panel mount. This model still includes the semi-auto plus manual drain and a fitted gauge.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.