The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR500N20LWK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 3/4" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR500N20LWK is a filter and regulator combined into a single body, so the incoming air is spun to separate liquid water and solid particles before being set to a steady outlet pressure. This 3/4in unit works in the lower 0.15-0.4 MPa (20-58 psi) band and uses a 5 um element for finer filtration.
A pressed-in self-locking knob resists set-pressure drift from vibration, and the balanced mechanism holds the outlet steady as supply pressure varies. The nylon bowl collects condensate, and the unit weighs 950 g, so it needs a proper panel or frame mount rather than support from the tubing.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR500N20LWK |
|---|---|
| Series | GAFR500 filter & regulator |
| Port size | 3/4" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 108 cc |
| Bracket | Included |
| Weight | 950 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code. This unit filters and regulates only; it does not add lubrication.
| GAFR500 | GA500 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 20 | Port size 3/4". This body offers 20 = 3/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Mounting bracket included. |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC500-20 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR500 · 3/4" · curve to 8000 L/min |
|---|---|
| One size down | GAFR400 |
| One size up | GAFR600 (curve to 12000 L/min) |
| Add a lubricator | GAFC500-20 (F.R.L. combination) |
Feed a bank of precision pneumatic valves that require a stable, lower regulated pressure and clean air. The 5 um element traps fine particles that could clog small orifices.
Maintain a gentle, consistent pressure on a conveyor belt tensioning cylinder. The lower 0.4 MPa ceiling suits light-duty applications where higher force is not needed.
Provide filtered, regulated air to a laboratory test bench or calibration rig. The 3/4in port supports moderate flow while the 5 um element protects sensitive instruments.
Choose the GAFR500 body for a 3/4in port with a 108 cc drain bowl and a flow curve plotted to 8000 L/min at 0.7 MPa inlet. The nylon bowl is a build choice with the same 1.0 MPa max and -5 to 70 C rating as PC or metal, so confirm compatibility for aggressive surroundings. This model has the semi-auto and manual drains both fitted, a 5 um element, the mounting bracket included, and a circular gauge with MPa/psi scale. The L type tops out at 0.4 MPa; if the machine may ever need more, L is the wrong part. The reverse-flow (reflux) valve is fitted as an ordering difference. If oil is needed downstream, order the matching GAFC500-20 combination instead. 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC500-20 combination; do not expect an oil mist from this unit.
The GAFR500N20LWK is a filter & regulator with a 3/4in port, working pressure range of 0.15-0.4 MPa (20-58 psi), max pressure of 1.0 MPa (145 psi), proof pressure of 1.5 MPa (215 psi), and temperature range of -5 to 70 C. It has a 108 cc drain bowl and weighs 950 g. The unit uses a 5 um element and has a semi-auto plus manual drain.
The K code means the reverse-flow (reflux) valve is fitted. It is an ordering difference from models without the K. The catalogue defers the function of this valve to a separate page, so its operation is not detailed here.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.