The AirTAC Airtac GAFR Adjustable Filter Regulator GAFR600C20ASJN is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 3/4" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR600C20ASJN is a filter and regulator combined into a single robust body, eliminating the need for separate units. This 3/4in port model handles high-flow lines with a 40 um element and an automatic drain, all within a 0.15-0.9 MPa (20-130 psi) working range.
Its 1880 g weight and metal bowl signal a heavy-duty build for industrial headers. The diversion structure spins air to separate liquid water and solid particles into the 205 cc condensate bowl, while the balanced regulator holds the set outlet pressure steady as supply varies.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR600C20ASJN |
|---|---|
| Series | GAFR600 filter & regulator |
| Port size | 3/4" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 205 cc |
| Bracket | Not included (J) |
| Weight | 1880 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFR600 is 1/4" if you add one. This unit filters and regulates only; it does not add lubrication.
| GAFR600 | GA600 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: Metal (C) only. |
| 20 | Port size 3/4". This body offers 20 = 3/4", 25 = 1". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) only. |
| J | No bracket (J) — supplied without the mounting bracket. |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC600-20 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR600 · 3/4" · curve to 12000 L/min |
|---|---|
| One size down | GAFR500 |
| Add a lubricator | GAFC600-20 (F.R.L. combination) |
Feed a multi-station assembly machine with a single 3/4in line, using the automatic drain to handle condensate without manual checks.
Supply a long conveyor line with multiple actuators, relying on the 205 cc bowl to reduce drain frequency and the steady regulator to maintain consistent pressure.
Mount on a process skid where the 1880 g weight and metal bowl suit a permanent installation, with the no-gauge option simplifying the panel layout.
Choose the GAFR600 for large machine headers or multi-station lines where the 12000 L/min plotted flow envelope at 0.7 MPa inlet is needed. This model has a metal bowl (C), an automatic drain (A), and no mounting bracket (J) - plan for panel mounting or an existing frame. The standard pressure type (S) covers 0.15-0.9 MPa (20-130 psi), and the 40 um element is the default; select the W option for 5 um filtration. No gauge is fitted (N), but the 1/4in gauge connection is ready for a field-installed unit. If oil is needed downstream, order the matching GAFC600-20 combination instead. With a 1.0 MPa max supply, you have about 0.1 MPa above the 0.9 MPa top of the regulated range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC600-20 combination; do not expect an oil mist from this unit.
Working pressure is 0.15-0.9 MPa (20-130 psi), with a 1.0 MPa (145 psi) maximum and 1.5 MPa (215 psi) proof pressure. Temperature range is -5 to 70 C. The drain bowl holds 205 cc and the unit weighs 1880 g.
The N code means no gauge is supplied, leaving a 1/4in connection for a field-installed gauge. The J code omits the mounting bracket, so you must use an existing bracket or panel mount. Both options reduce initial cost when these features are already present.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.