verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC200-06 FRL Unit (GC20006MLF1)

The AirTAC AirTAC GC200-06 FRL Unit (GC20006MLF1) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$60.43 $65.62Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC200-06 drain, gauge and thread option on one page All GC200-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC200-06 FRL Unit (GC20006MLF1)

The GC200 series is AirTAC's three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator so one inlet run cleans, regulates and lubricates the compressed air. This GC20006MLF1 is the size-200 body with a 1/8 inch PT port, a manual-drain polycarbonate filter bowl, the standard 40 um element, a low-pressure type regulator and an embedded square gauge reading in MPa.

Every set we sell is a genuine AirTAC part. The GC range runs from size 200 to 600 with ports from 1/8 inch to 1 inch, and can be ordered with a 40 um or 5 um element, differential-pressure, automatic or manual drain, square or round gauges in MPa, psi or bar scales, and G (BSPP) or NPT threads instead of the PT standard. Flow figures are published as curves rather than a single rating, so send us your line details and we will confirm the datasheet numbers on request.

AirTAC GC200-06 FRL Unit (GC20006MLF1) Technical Specifications

ModelAirTAC GC200-06 FRL Unit (GC20006MLF1)
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/8" (PT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC200-06 FRL Unit (GC20006MLF1)

GC200G-series F.R.L. combination, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/8" · 40 µm
One size upGC300
Two-unit equivalentGFC200-06
Build orderFilter → regulator → lubricator

Where the AirTAC GC200-06 FRL Unit (GC20006MLF1) Is Used

factory

Bottling plant filler actuators

Conditioning the air that drives fill-head lift cylinders and capping-clamp actuators on a small beverage filling line.

air

Furniture workshop spray station

Filtering, regulating and oil-misting the supply to air-fed finishing guns and hold-down clamps at a woodworking spray bench.

settings_input_component

Pneumatic control panel feed

Supplying stable, clean, lubricated air to a panel of directional control valves on an assembly-machine manifold.

Is the AirTAC GC200-06 FRL Unit (GC20006MLF1) the Right Station?

Size 200 is the smallest GC step with a 1/8 inch PT port; move up to 300, 400 or 600 as demand grows. The M code gives a manual-drain filter bowl, convenient where the set is reachable; automatic and differential-pressure drains exist on other codes. This unit keeps the 40 um standard element, and the square gauge reads in MPa (psi and bar scales can be ordered). This is the low-pressure type regulator - confirm the adjustment span for your line pressure with us before ordering. Thread is PT as standard; G (BSPP) and NPT are catalogue options. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.

AirTAC GC200-06 FRL Unit (GC20006MLF1) FAQ

AirTAC publishes flow for the GC range as performance curves rather than one rated figure, so we do not state a number here. Share your line pressure and consumption and we will confirm the correct size from the datasheet on request.

Units with a regulator carry an embedded square gauge, and MPa, psi or bar scales can be specified; an external round gauge is available on other codes, and gaugeless versions (N) exist too. Tell us what you want to read and we will confirm the option on request.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC200-06 FRL Unit (GC20006MLF1)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC20006MLF1 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.