verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC200-06 FRL Unit (GC20006NK)

The AirTAC AirTAC GC200-06 FRL Unit (GC20006NK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$66.14 $71.46Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC200-06 drain, gauge and thread option on one page All GC200-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC200-06 FRL Unit (GC20006NK)

The GC series is AirTAC's three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator supplied as one ordered set. This GC20006NK is the size 200 frame with PT1/8 ports, the standard 40 um filter element, the differential-pressure drain, the reverse (check) valve fitted and no pressure gauge. In use it filters, regulates and lubricates a single compressed-air line: maximum working pressure is 1.0 MPa (145 psi), working temperature is -5 to 70 C (non-freezing), the bowls are polycarbonate at size 200, and the regulator adjusts from 0.15 to 0.9 MPa (20-130 psi).

This is a genuine AirTAC part sold through airtacdistr.com for the US market. The G series spans sizes 200, 300, 400 and 600 with ports from 1/8 in. to 1 in., and each size can be ordered with automatic, manual or differential-pressure drain, 40 um or 5 um filtration, an embedded square gauge or external round gauge in MPa, psi or bar scale, and G(BSPP) or NPT thread in place of the standard PT. GC-series flow is published as curves rather than a single rated figure, so we confirm datasheet figures for your application on request.

AirTAC GC200-06 FRL Unit (GC20006NK) Technical Specifications

ModelAirTAC GC200-06 FRL Unit (GC20006NK)
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/8" (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC200-06 FRL Unit (GC20006NK)

GC200G-series F.R.L. combination, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/8" · 40 µm
One size upGC300
Two-unit equivalentGFC200-06
Build orderFilter → regulator → lubricator

Where the AirTAC GC200-06 FRL Unit (GC20006NK) Is Used

precision_manufacturing

Small CNC machine tool air supply

Conditions the air feeding tool-change cylinders and air blast on a compact CNC lathe or mill, with the reverse (check) valve preventing backflow through the set if the shop supply is isolated.

build

Robotic gripper station feed

Prepares air for gripper and clamp cylinders on a robotic pick-and-place cell, where the check valve helps hold the set's downstream side against reverse flow from the manifold.

cable

Wire and cable cutting station

Supplies the hold-down clamps and cutter cylinder of a wire processing bench, keeping the standard 40 um grade ahead of the machine's valves while the differential-pressure drain handles condensate in service.

Is the AirTAC GC200-06 FRL Unit (GC20006NK) the Right Station?

Size 200 with PT1/8 ports is the smallest step in the GC range; step up to sizes 300, 400 or 600 as demand grows beyond a 1/8 in. connection. The blank drain position is the differential-pressure drain, AirTAC's standard, with automatic (A) and manual (M) drains available to order. The 40 um element is the standard grade for general line protection; order the W suffix where the finer 5 um element is wanted. The trailing K on this code means the reverse (check) valve is fitted - the equivalent GC20006N ships without it. No gauge is fitted; a square or round gauge in MPa, psi or bar scale can be ordered. Thread is standard PT, with G(BSPP) and NPT as catalogue options.

Flow for the GC series is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.

AirTAC GC200-06 FRL Unit (GC20006NK) FAQ

AirTAC publishes GC-series flow as performance curves rather than a single rated figure, so we do not quote one number on this page. Send us your line pressure and air demand and we will confirm the flow and datasheet figures for this exact unit on request before you order.

K is AirTAC's code for a reverse (check) valve fitted to the unit, which blocks reverse flow through the combination. The same unit without the K suffix, GC20006N, carries no reverse valve; both share the same size 200, PT1/8, 40 um, differential-pressure-drain configuration.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC200-06 FRL Unit (GC20006NK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC20006NK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.