verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC200-08 FRL Unit (GC20008C1K)

The AirTAC AirTAC GC200-08 FRL Unit (GC20008C1K) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$71.79 $77.26Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC200-08 drain, gauge and thread option on one page All GC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC200-08 FRL Unit (GC20008C1K)

The GC series is AirTAC's three-piece F.R.L. combination: a separate air filter, pressure regulator and lubricator built as one supply set for compressed air. This GC200-08K configuration is the 200 size with a 1/4 inch PT-threaded port, a differential-pressure drain on the filter bowl and the standard 40 um element. The regulator is the standard type with an adjustment range of 0.15-0.9 MPa (20-130 psi), the C1 code adds an external round pressure gauge reading in MPa, and the K code fits a reverse/check valve. Maximum inlet pressure is 1.0 MPa (145 psi); working temperature is -5 to 70 C, non-freezing. The 200-size filter bowl is polycarbonate (PC).

This is a genuine AirTAC part offered by airtacdistr.com for the US market. The G series spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, plus options for G (BSPP) or NPT threads, automatic, manual or differential-pressure drains, 5 um or 40 um elements, gauges in MPa, psi or bar scales, and the reverse/check valve. Flow for the series is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before ordering.

AirTAC GC200-08 FRL Unit (GC20008C1K) Technical Specifications

ModelAirTAC GC200-08 FRL Unit (GC20008C1K)
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC200-08 FRL Unit (GC20008C1K)

GC200G-series F.R.L. combination, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/4" · 40 µm
One size upGC300
Two-unit equivalentGFC200-08
Build orderFilter → regulator → lubricator

Where the AirTAC GC200-08 FRL Unit (GC20008C1K) Is Used

valve

Process valve actuation skid

Conditions air for quarter-turn pneumatic valve actuators on a water treatment skid; the check valve keeps the actuator circuit charged if the header supply dips.

build

Robot end-effector air supply

Feeds filtered, regulated and lubricated air to gripper and clamp circuits on a robotic handling cell, with the MPa gauge visible for setup checks at the cell panel.

view_module

Panelised clamping fixture feed

Supplies the pneumatic clamps across a modular welding fixture, where the fitted check valve helps hold clamp pressure against momentary supply fluctuations.

Is the AirTAC GC200-08 FRL Unit (GC20008C1K) the Right Station?

Size 200 with a 1/4 inch port covers most general machine supply points; move to 300, 400 or 600 where your circuit needs larger ports and greater flow capacity. The differential-pressure drain clears the bowl automatically during operation; automatic (A) and manual (M) drain codes are available if preferred. The K code adds the reverse/check valve - choose it where you want the downstream circuit held if supply pressure drops. The C1 gauge reads in MPa; psi and bar scales and square gauges exist in the series. Thread is PT as standard; order the G (BSPP) or T (NPT) variant for other piping. Flow is published as curves, not a single rating, so ask us to confirm sizing against the datasheet before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.

AirTAC GC200-08 FRL Unit (GC20008C1K) FAQ

AirTAC publishes flow for the G series as curves rather than a single rated figure, so no single number is quoted here. Share your required flow and working pressure and we will confirm the correct size from the datasheet before you order.

K specifies that a reverse/check valve is fitted, so downstream pressure is held if the upstream supply fails or drops - useful on clamping and holding circuits. The GC20008C1 without the K carries no check valve.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC200-08 FRL Unit (GC20008C1K)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC20008C1K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.