verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC200-08 FRL Unit (GC20008C1WK)

The AirTAC AirTAC GC200-08 FRL Unit (GC20008C1WK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$71.79 $77.26Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC200-08 drain, gauge and thread option on one page All GC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC200-08 FRL Unit (GC20008C1WK)

The AirTAC GC series is a three-unit F.R.L. combination: a separate air filter, a pressure regulator and a lubricator, giving filtration, regulation and oil-mist lubrication in one set. This GC20008C1WK is the size 200 unit with PT1/4 (1/4 inch PT) ports, a 5 um filter element (the finer W option instead of the 40 um standard), a differential-pressure drain, a round pressure gauge with MPa scale, and a reverse (check) valve fitted.

This is a genuine AirTAC part. The G series is offered in sizes 200, 300, 400 and 600 with port options up to 1 inch and thread options PT (standard), G and NPT. Maximum working pressure is 1.0 MPa (145 psi), temperature range is -5 to 70 C (non-freezing), and the regulator set range on this differential-drain version is 0.15-0.9 MPa (20-130 psi). Published flow data appears as curves rather than a single rated figure, so we confirm sizing and datasheet details on request.

AirTAC GC200-08 FRL Unit (GC20008C1WK) Technical Specifications

ModelAirTAC GC200-08 FRL Unit (GC20008C1WK)
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC200-08 FRL Unit (GC20008C1WK)

GC200G-series F.R.L. combination, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/4" · 5 µm
One size upGC300
Two-unit equivalentGFC200-08
Build orderFilter → regulator → lubricator

Where the AirTAC GC200-08 FRL Unit (GC20008C1WK) Is Used

precision_manufacturing

Pneumatic clamping on a machining cell

Filtered, regulated and lubricated air for clamp cylinders on a small CNC or milling fixture, with the round MPa gauge letting the operator read the clamping pressure directly.

air

Spray-gun supply on a paint line

The 5 um element and oil-mist lubrication suit air-fed spray guns in a small paint or finishing booth where clean, lubricated air reaches the gun.

settings_input_component

Pick-and-place module with check valve

A gripper or pick-and-place circuit where the fitted reverse (check) valve is part of the specified configuration; exact behaviour is detailed in the datasheet we provide on request.

Is the AirTAC GC200-08 FRL Unit (GC20008C1WK) the Right Station?

Size 200 is the compact entry of the G series with 1/4 inch ports; if your line needs more air, step up to sizes 300, 400 or 600, which have larger ports and higher flow capability. The differential-pressure drain is the default; order the A suffix for automatic drain or M for manual drain (manual changes the regulator range to 0.05-0.9 MPa / 7-130 psi). The 5 um W element suits cleaner-downstream work; the 40 um standard element suits general plant air.

The C1 gauge code here is the external round gauge with MPa scale; psi and bar scales are also catalogue options. PT thread is the standard; G (BSPP) and NPT versions can be ordered as specification options. Because flow for this family is published as curves and not as a single rating, please ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.

AirTAC GC200-08 FRL Unit (GC20008C1WK) FAQ

AirTAC publishes flow for this family as curves rather than a single rated figure, so no single flow number is stated here. Ask us and we will confirm the flow curve and datasheet figures against your application before you order.

K means a reverse (check) valve is fitted in this configuration. Drain-wise, this version uses the differential-pressure drain, the default for the GC family; automatic (A) and manual (M) drain versions are also catalogue options.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC200-08 FRL Unit (GC20008C1WK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC20008C1WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.