The AirTAC AirTAC GC200-08 FRL Unit (GC20008C3) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC series is a three-unit F.R.L. combination: a separate air filter, a pressure regulator and a lubricator covering filtration, regulation and oil-mist lubrication. This GC20008C3 is the size 200 unit with PT1/4 (1/4 inch PT) ports, the standard 40 um filter element, a differential-pressure drain, and a round pressure gauge with bar scale.
This is a genuine AirTAC part. The G series spans sizes 200 to 600 with ports up to 1 inch and thread options PT (standard), G and NPT. Maximum working pressure is 1.0 MPa (145 psi), temperature range is -5 to 70 C (non-freezing), and the regulator set range on this differential-drain version is 0.15-0.9 MPa (20-130 psi). Because flow is published as curves and not as a single rated figure, we confirm sizing and datasheet details on request.
| Model | AirTAC GC200-08 FRL Unit (GC20008C3) |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/4" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, bar scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 3 | Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · PT1/4" · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-08 |
| Build order | Filter → regulator → lubricator |
Filtered, regulated and lubricated air for small pneumatic process and divert valves on a filling or bottling line, with the bar gauge matching metric plant documentation.
One conditioned air drop feeding stoppers, gates and pushers along a conveyor section, combining all three FRL functions in a single set.
An engineering test bench running small air cylinders and actuators, where the regulator sets the test pressure and the bar gauge gives a direct metric reading.
Size 200 is the 1/4 inch-port entry of the G series; sizes 300, 400 and 600 carry larger ports and greater flow capability. The differential-pressure drain is the default; the A (automatic) and M (manual) suffixes are catalogue alternatives, with manual drain extending the regulator range to 0.05-0.9 MPa (7-130 psi). The 40 um element is the standard grade; specify W for the 5 um element.
The C3 gauge code is the external round gauge with bar scale, alongside MPa and psi scale options. PT is the standard thread, with G (BSPP) and NPT versions orderable as specifications. Flow for this family appears only as curves, not a single rating, so please ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.
No single rated flow number exists for this family - AirTAC publishes flow as curves. Contact us with your application and we will confirm the flow curve and full datasheet figures before you order.
The C3 code selects the external round gauge with a bar scale; MPa (C1) and psi (C2) scales are also available. Drain, filter grade, thread and port on this model follow the defaults: differential-pressure drain, 40 um element, PT thread, 1/4 inch ports.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.