The AirTAC AirTAC GC200-08 FRL Unit (GC20008LF1) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC20008LF1 is a genuine AirTAC G-series three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator installed in line as one set. The 200 size is built for 1/4 in PT ports. The filter element is the standard 40 um grade and the bowls drain by differential pressure, the regulator is the low-pressure (L) type, and the F in the code selects the square pressure gauge with an MPa scale instead of the round style. One installation filters water and particulate, holds a set downstream pressure and adds oil mist.
This is a genuine AirTAC part from the G series, which spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in. Series options include G (BSPP) or NPT threads, manual or automatic drains, a 5 um element and a round gauge. Maximum working pressure is 1.0 MPa (145 psi) and the temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so we confirm the datasheet and sizing on request.
| Model | AirTAC GC200-08 FRL Unit (GC20008LF1) |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/4" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · PT1/4" · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-08 |
| Build order | Filter → regulator → lubricator |
Conditioning the air feed to the suction and clamp grippers on a palletiser, with the square gauge easy to read from the line side.
Supplying clean, regulated, oiled air to nailers and staplers at a furniture workshop bench drop.
Adding filtration, regulation and lubrication when fitting a pneumatic clamp or ejection cylinder to an older machine as part of a retrofit.
This 200-size set suits 1/4 in PT lines; step up to the 300, 400 or 600 size for larger ports and more flow. With the differential-pressure drain, the regulator adjusts over 0.15-0.9 MPa (20-130 psi), and the manual-drain variant lowers the bottom of the range. The L marks the low-pressure regulator type, so confirm very low settings with us before ordering. The standard 40 um element is fitted here; the W version gives 5 um filtration. Thread is PT as standard, with G (BSPP) and NPT as catalogue options, and the square MPa gauge in this code can be swapped for the round style or another scale. AirTAC publishes flow as curves, not a single rated figure, so ask us to confirm sizing against your application before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.
AirTAC publishes flow for the G series as curves rather than a single rated figure, so we do not quote a number here. Tell us your line pressure and air demand and we will confirm the correct size and provide the datasheet on request.
Both show the same regulated pressure; the F in this code selects the square gauge with an MPa scale, while the standard C code carries the round style. psi and bar scales are also catalogue options. Function and connections are otherwise identical: 1/4 in PT ports, 40 um element, differential-pressure drain.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.