The AirTAC AirTAC GC200-08 FRL Unit (GC20008MF1W) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).
The AirTAC GC series is a three-unit air preparation combination: a separate filter, pressure regulator and lubricator that together clean, regulate and oil-mist lubricate compressed air. This GC20008MF1W is the 200 size with PT1/4 ports, fitted with the finer 5 um W-grade filter element, a manual drain on the filter bowl, an embedded square pressure gauge scaled in MPa, and the standard regulator with a 0.05-0.9 MPa (7-130 psi) setting range.
It is a genuine AirTAC part rated for compressed air at up to 1.0 MPa (145 psi) working pressure between -5 and 70 C (non-freezing). The GC range steps through 200, 300, 400 and 600 sizes with ports from 1/8 to 1 inch, and drain, filter grade, gauge and thread options to suit the installation. Because flow is published as curves rather than a single rated figure, we confirm the datasheet and sizing on request.
| Model | AirTAC GC200-08 FRL Unit (GC20008MF1W) |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/4" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · PT1/4" · 5 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-08 |
| Build order | Filter → regulator → lubricator |
Supplying an array of compact pick-and-place modules on an electronics assembly line, where the 5 um W-grade element suits the fine valve and cylinder circuits and the lubricator conditions the actuators.
Conditioning air ahead of the actuation and atomizing circuits on a paint line, with the finer 5 um grade as specified and the regulator set from the embedded MPa gauge.
A tidy three-in-one feed for maintenance-shop outlets and pneumatic test rigs: 5 um filtration, a settable regulator with MPa gauge, and lubrication for the tools connected downstream.
Size to air demand first: the 200 body with 1/4 inch PT ports serves lighter branch lines, and the 300, 400 and 600 sizes above it carry progressively more flow on larger ports. The W in this code selects the 5 um element instead of the standard 40 um grade - choose it where fine downstream valves or instruments are fed, and stay at 40 um for general-purpose circuits. The manual drain needs periodic attention; automatic and differential-pressure drains are the alternatives. The embedded square gauge reads MPa, with round gauges and psi or bar scales as options, and threads are PT as standard with G (BSPP) and NPT available. Flow is published as curves, not one rated number, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.
Flow for the GC series is published as pressure-drop curves, not as a single rated figure, so there is no one number we can quote. Tell us your line pressure and air demand and we will confirm the correct size and the datasheet figures on request before you order.
The blank position selects the standard 40 um element, which suits general-purpose tool and cylinder circuits; W selects the 5 um grade for finer filtration where precision valves or instruments are downstream. Both are catalogue options on this same GC20008 set, so the choice only changes the code.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.