verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

Airtac GC FRL Unit GC200C06C1W

The AirTAC Airtac GC FRL Unit GC200C06C1W is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$71.79 $77.26Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GC FRL Unit GC200C06C1W

GC200C06C1W is a genuine AirTAC G-series three-piece F.R.L. combination: a separate filter, regulator and lubricator assembled into one air-treatment station. It removes water and particulate, holds downstream pressure steady and meters oil mist to the equipment being fed. This 200-size set is specified with PT1/8 ports, a differential-pressure drain, a fine 5 um filter element for cleaner air than the standard grade, and a round pressure gauge marked in MPa.

The G-series is offered in 200, 300, 400 and 600 sizes with ports from 1/8 to 1 inch and PT, G or NPT threads, so the same family can serve larger branches later. Maximum working pressure is 1.0 MPa (145 psi), the standard temperature range is -5 to 70 C (non-freezing), and the PC bowls are intended for indoor duty. Flow is published as curves rather than a single rating, so share your application details and we will confirm the figures and the full datasheet on request.

Airtac GC FRL Unit GC200C06C1W Technical Specifications

ModelAirtac GC FRL Unit GC200C06C1W
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GC FRL Unit GC200C06C1W

GC200G-series F.R.L. combination, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · See datasheet · 40 µm
One size upGC300
Two-unit equivalentGFC200-C0
Build orderFilter → regulator → lubricator

Where the Airtac GC FRL Unit GC200C06C1W Is Used

factory

Bottle-filling line cylinders

Treating the plant air that strokes filling and capping cylinders on a beverage line, where the 5 um element helps protect the tight-tolerance pilot valves these machines rely on.

handyman

Maintenance bench air tools

A wall-mounted station for impact wrenches and ratchets at a maintenance bench, delivering filtered, regulated and oiled air from a single PT1/8 connection point.

science

Laboratory test-rig air supply

Conditioning compressed air for a laboratory test rig, where the fine 5 um grade helps keep pneumatic instrumentation and quick-connect fittings free of debris.

Is the Airtac GC FRL Unit GC200C06C1W the Right Station?

This 200-size set carries PT1/8 ports; if the branch needs more air, GC300, GC400 and GC600 are the catalogue steps up. The differential-pressure drain is the default here, with automatic (A) and manual (M) drain versions available as catalogue options. The 5 um element on this code suits tighter applications such as pilot valves and instrumentation; the standard grade is 40 um. With the differential drain, the regulator set point ranges 0.15-0.9 MPa (20-130 psi), and the round gauge reads in MPa, with psi and bar scales available as options. PT thread is the standard on this code, with G (BSPP) and NPT orderable as specifications. Because G-series flow is published as curves rather than one rating, ask us to check the datasheet against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.

Airtac GC FRL Unit GC200C06C1W FAQ

We do not quote a single rated number because AirTAC publishes G-series capacity as flow curves. Send us your working pressure and the air demand of your equipment, and we will confirm the correct size against the datasheet on request.

This code carries the differential-pressure drain, which works off the pressure drop across the filter element. Automatic (A) and manual (M) drain versions are catalogue options if you want unattended condensate removal or a fixed drain interval instead.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GC FRL Unit GC200C06C1W

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC200C06C1W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.