The AirTAC Airtac GC FRL Unit GC200C06MC1K is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC series is AirTAC's three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator supplied as a set so one point of conditioning removes water and particulate, holds a set downstream pressure and meters a controlled oil mist into the air stream. This GC200C06MC1K is the 200 size with PT1/8 ports, a manually drained filter bowl, the standard 40 um filter element and a round external MPa-scale gauge, and per the K suffix a reverse/check valve is fitted. With manual drainage the regulator sets from 0.05 to 0.9 MPa (7-130 psi), and maximum working pressure is 1.0 MPa (145 psi).
This is a genuine AirTAC part. The G series spans 200, 300, 400 and 600 sizes with ports from 1/8 to 1 inch; PT thread is the standard with G (BSPP) and NPT as catalogue options. Filter bowls in this 200 size are polycarbonate (PC), and the temperature range is -5 to 70 C, non-freezing. Drain type, the 5 um element, gauge types and scales, and the reverse valve are all selectable within the series. AirTAC publishes flow as curves rather than a single rated figure, so ask us to confirm flow and datasheet details for your application.
| Model | Airtac GC FRL Unit GC200C06MC1K |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
Feeding clamp cylinders on a machining fixture from a 1/8-inch line, where the three-unit set conditions the supply and the K-specified reverse/check valve is fitted as part of the order code.
Conditioning air to the valve-and-cylinder block of a compact pick-and-place head, keeping the filter, regulator and lubricator functions in one ordered set with a manual drain bowl.
Supplying the ram and ejector cylinders of a bench-mounted pneumatic press, with the MPa round gauge letting operators verify set pressure at a glance during setup.
Step up or down through the 200, 300, 400 and 600 sizes to match the port and flow your circuit needs; this unit is the 200 size with PT1/8 ports. The M in the code fixes a manual drain, which widens the regulator setting range to 0.05-0.9 MPa (7-130 psi); automatic and differential-pressure drain versions set from 0.15-0.9 MPa (20-130 psi). The standard element is 40 um; add W for 5 um. The C1 gauge code fits the round external gauge on the MPa scale, with embedded square gauges and psi or bar scales as catalogue choices. The K suffix specifies that the reverse/check valve is fitted; we can confirm its exact behaviour on the datasheet on request. Thread is PT as standard with G (BSPP) and NPT as orderable options, and the bowl on this 200 size is polycarbonate. Flow is published as curves, not a single rating, so ask us to confirm sizing before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
AirTAC publishes G-series flow as curves rather than a single rated figure, so there is no single number to quote here. Give us your supply pressure, downstream demand and allowable pressure drop and we will confirm sizing from the datasheet on request before you order.
C1 is the gauge code: a round external pressure gauge on the MPa scale is fitted, while the embedded square gauge and psi (scale 2) or bar (scale 3) versions are catalogue choices. K specifies that the reverse/check valve is fitted; ask us to confirm its behaviour in your circuit on the datasheet.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.