verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC300-08 FRL Unit (GC30008AC3)

The AirTAC AirTAC GC300-08 FRL Unit (GC30008AC3) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$98.12 $104.24Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-08 drain, gauge and thread option on one page All GC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC300-08 FRL Unit (GC30008AC3)

The GC series combines a separate air filter, pressure regulator and lubricator into one three-unit F.R.L. set. This configuration is size 300 with 1/4 in PT ports, an automatic-drain filter bowl and the standard 40 um element. A round external pressure gauge on bar scale is included, and there is no reverse valve in the air path. With the automatic drain, the regulator adjustment range is 0.15 to 0.9 MPa (20 to 130 psi).

This is a genuine AirTAC part. Maximum working pressure is 1.0 MPa (145 psi), working temperature is -5 to 70 C (non-freezing), and the bowls are polycarbonate (PC) at this size. Across the GC range you can specify sizes 200 to 600, manual or differential-pressure drains, 5 um fine elements, other gauge scales and G or NPT threads. Flow is published as curves rather than a single rating, so ask us and we will confirm the datasheet figures on request.

AirTAC GC300-08 FRL Unit (GC30008AC3) Technical Specifications

ModelAirTAC GC300-08 FRL Unit (GC30008AC3)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, bar scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-08 FRL Unit (GC30008AC3)

GC300G-series F.R.L. combination, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
3Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-08 filter, GR300-08 regulator and GL300-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/4" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-08
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-08 FRL Unit (GC30008AC3) Is Used

air

Furniture finishing booth

Conditions the compressed air serving a spray-finishing booth's agitators, blow-off guns and tool drops, with one regulated set pressure and one lubrication point for the booth's air tools.

build

Fixture clamping rig

Feeds pneumatic swing clamps and supports on a machining fixture, giving filtered, regulated and lubricated air so the clamping circuit holds a consistent set pressure part after part.

settings_input_component

Diverter valve actuators

Supplies the cylinder actuators on gate and diverter valves in a bulk-material handling line, with the automatic drain keeping condensate out of the actuator supply.

Is the AirTAC GC300-08 FRL Unit (GC30008AC3) the Right Station?

Size 300 with 1/4 in PT ports covers mid-range machine supplies; sizes 200, 400 and 600 are the steps either side. Drain is automatic here, so no manual blow-down is needed - M and the blank differential-pressure option are the alternatives. The 40 um element is the standard grade; add W for 5 um. The C3 code selects a round gauge in bar; C1 (MPa) and C2 (psi) are the other scales, and the no-code default is the embedded square gauge. Thread is PT as standard, with G (BSPP) and NPT as catalogue options. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-08 regulator with a GF300-08 filter on that branch.

AirTAC GC300-08 FRL Unit (GC30008AC3) FAQ

Flow for the G series is published as curves rather than a single rated figure, so we do not state one number here. Tell us your application and we will confirm the datasheet flow curve and sizing for GC30008AC3 on request.

The A code fits an automatic drain, which discharges collected condensate from the filter bowl without operator attention. The alternatives are M for a manual drain and a blank code for the differential-pressure drain, which you choose when decoding the set.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC300-08 FRL Unit (GC30008AC3)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30008AC3 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.