The AirTAC AirTAC GC300-08 FRL Unit (GC30008AF1W) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC30008AF1W is a three-unit AirTAC G-series F.R.L. combination - separate filter, regulator and lubricator for 1/4 in (PT1/4) ports - specified with the fine 5 um filter element. Combined with the automatic-drain bowl and the embedded square gauge scaled in MPa, this configuration gives finer particle removal than the standard element ahead of regulation, self-emptying condensate handling, and metered oil mist for downstream equipment.
This is a genuine AirTAC part. The G series is available in 200, 300, 400 and 600 sizes, carries compressed air only up to 1.0 MPa (145 psi) working pressure at -5 to 70 C, and uses polycarbonate bowls at the 300 size. Flow is published as curves rather than a single rating, so we confirm flow and other datasheet figures on request.
| Model | AirTAC GC300-08 FRL Unit (GC30008AF1W) |
|---|---|
| Series | GC300 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/4" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC300 | G-series F.R.L. combination, 300 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-08 filter, GR300-08 regulator and GL300-08 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC300 · PT1/4" · 5 µm |
|---|---|
| One size down | GC200 |
| One size up | GC400 |
| Two-unit equivalent | GFC300-08 |
| Build order | Filter → regulator → lubricator |
Multi-station assembly machines run cylinders thousands of times per shift; the 5 um element reduces fine particle wear on seals and bores while the lubricator maintains the oil film.
Bench rigs with air-operated clamps, comparators and actuation fixtures behave more repeatably on finer-filtered air, and the MPa-scale square gauge supports documented test setups.
Air motors on roll-winding stands need continuous lubrication and tolerate grit poorly; this set delivers oiled, finely filtered air while the automatic drain handles condensate through long runs.
Pick the W suffix when the 40 um standard element is too coarse for the components you are protecting - the 5 um option is coded directly in the part number. The rest of this code is the mid-range 300 size with 1/4 in PT ports, automatic drain (manual and differential-pressure variants exist, with 0.15-0.9 MPa / 20-130 psi adjustment for automatic and differential drains) and the embedded square MPa gauge; psi or bar scales and an external round gauge are catalogue options, as are G (BSPP) and NPT threads in place of the PT standard. Because flow is published as curves rather than a single rating, ask us to confirm the sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-08 regulator with a GF300-08 filter on that branch.
AirTAC does not publish a single rated flow for the G series - performance is given as characteristic curves, so any one-number claim would be an estimate. Send us your duty flow and pressure and we will confirm the fit against the datasheet curves on request before you order.
Choose the 5 um W element when the downstream equipment has close-tolerance valves, fine seals or repeatability requirements that coarser 40 um filtration does not suit; keep 40 um for general-purpose shop air. Both grades are catalogue options across the GC filter, filter-regulator and F.R.L. families.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.