AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC300-08 FRL Unit (GC30008ALNW)

The AirTAC AirTAC GC300-08 FRL Unit (GC30008ALNW) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$92.47 $98.45Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-08 drain, gauge and thread option on one page All GC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC300-08 FRL Unit (GC30008ALNW)

The GC30008ALNW is a genuine AirTAC G-series three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator set up for compressed-air treatment in one assembly. This configuration has PT1/4 ports, a 5 um (W) filter element for finer particulate removal than the standard 40 um element, and an automatic drain on the filter bowl so collected condensate is expelled without manual attention. The L code selects the low-pressure regulator type, intended for circuits where the downstream pressure must be held well below full line pressure; contact us to confirm the exact adjustment band for this variant. No gauge is fitted (N code).

This is a genuine AirTAC part in the GC series, which spans 200, 300, 400 and 600 sizes with ports from 1/8" to 1" and PT, G (BSPP) or NPT threads. Filter grade, drain type, gauge option and thread are selectable at order stage. Flow for this series is published as curves rather than a single rated figure, so we confirm the datasheet and sizing on request.

AirTAC GC300-08 FRL Unit (GC30008ALNW) Technical Specifications

ModelAirTAC GC300-08 FRL Unit (GC30008ALNW)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-08 FRL Unit (GC30008ALNW)

GC300G-series F.R.L. combination, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-08 filter, GR300-08 regulator and GL300-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/4" · 5 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-08
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-08 FRL Unit (GC30008ALNW) Is Used

precision_manufacturing

Small CNC machining centre

Feeds filtered, lubricated and pressure-limited air to the machine's pneumatic tool-change and clamping circuits, with the 5 um element helping protect directional valves from fine contamination.

build

Paint spray booth supply

Conditions the air feeding spray guns on a finishing line, where the low-pressure regulator type suits gun supply pressures held well below the shop-air header.

conveyor_belt

Packaging machine actuation

Treats the air driving carton-forming and sealing cylinders on a packaging conveyor, with the automatic drain clearing condensate on an intermittently attended line.

Is the AirTAC GC300-08 FRL Unit (GC30008ALNW) the Right Station?

Size 300 with 08 ports gives you a 1/4" connection - the right step for compact machines and point-of-use drops; step up to 400/600 or down to 200 if your consumption sits at either edge of what a 1/4" line comfortably carries. This unit pairs an automatic drain (best where the filter is mounted away from daily reach) with the 5 um element (W) for finer protection of valves and cylinders, the low-pressure L regulator type, and no gauge - an external round gauge can be ordered as an option. PT thread is the standard; G (BSPP) and NPT are orderable thread options, and a mounting bracket is optional.

Because AirTAC publishes flow for the GC series as curves and not a single rating, ask us to check the curve against your line pressure and air consumption before you place the order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-08 regulator with a GF300-08 filter on that branch.

AirTAC GC300-08 FRL Unit (GC30008ALNW) FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not state a number here. Send us your line pressure and air consumption and we will confirm the flow curve and datasheet for the GC30008ALNW before you order.

L selects the low-pressure type of regulator, intended for downstream pressures held well below full line pressure - we confirm its exact adjustment band on request. W selects the 5 um filter element instead of the standard 40 um. A also means the filter bowl drains automatically.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC300-08 FRL Unit (GC30008ALNW)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30008ALNW and will confirm price, stock and lead time — usually within 7-8 hours.