verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC300-08 FRL Unit (GC30008ANK)

The AirTAC AirTAC GC300-08 FRL Unit (GC30008ANK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$103.82 $110.08Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-08 drain, gauge and thread option on one page All GC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC300-08 FRL Unit (GC30008ANK)

The GC30008ANK is a genuine AirTAC G-series three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator assembled as one set. This configuration has PT1/4 ports, the standard 40 um filter element, an automatic drain on the filter bowl, and the K option - a reverse (check) valve fitted, which holds the downstream circuit when upstream supply is lost. The standard regulator adjusts from 0.15 to 0.9 MPa (20-130 psi) with this auto-drain arrangement, and no gauge is fitted (N code).

This is a genuine AirTAC part in the GC series, spanning 200, 300, 400 and 600 sizes with ports from 1/8" to 1" and PT, G (BSPP) or NPT threads. Working pressure is up to 1.0 MPa (145 psi) and temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so we confirm the datasheet and sizing on request.

AirTAC GC300-08 FRL Unit (GC30008ANK) Technical Specifications

ModelAirTAC GC300-08 FRL Unit (GC30008ANK)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-08 FRL Unit (GC30008ANK)

GC300G-series F.R.L. combination, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-08 filter, GR300-08 regulator and GL300-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/4" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-08
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-08 FRL Unit (GC30008ANK) Is Used

engineering

Press clamp safety circuit

Supplies a pneumatic clamping circuit on a workholding press where the fitted check valve helps hold the clamped side if upstream air is interrupted.

conveyor_belt

Bottling line stopper gates

Treats the air for gate and stopper cylinders on a bottling conveyor, with the automatic drain handling condensate on a line that runs across shifts.

valve

Pneumatic valve manifold feed

Feeds a directional-valve manifold on process machinery, giving filtered, lubricated air at a regulated set point into a 1/4" distribution line.

Is the AirTAC GC300-08 FRL Unit (GC30008ANK) the Right Station?

Size 300 with 08 ports gives a 1/4" connection for point-of-use feeds; step to 200 or 400/600 depending on where your consumption sits. This unit adds the K option - a reverse (check) valve - which is worth specifying when the downstream circuit should hold its state if supply is interrupted. It keeps the standard 40 um element, the automatic drain, and the standard regulator type; a 5 um element, an external round gauge and G (BSPP) or NPT threads are all orderable options instead of the PT standard, and a mounting bracket is optional.

Because GC flow is published as curves rather than one rated figure, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-08 regulator with a GF300-08 filter on that branch.

AirTAC GC300-08 FRL Unit (GC30008ANK) FAQ

AirTAC publishes flow for the GC series as curves, not a single rated figure, so no number is stated here. Share your line pressure and air consumption and we will confirm the flow curve and datasheet for the GC30008ANK before you order.

K means a reverse (check) valve is fitted in this set. It allows normal flow in the treated direction and blocks reverse flow, helping hold the downstream circuit when upstream supply drops - a useful option on clamping and holding circuits. The other code letters set the 1/4" PT ports, automatic drain and standard 40 um element.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC300-08 FRL Unit (GC30008ANK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30008ANK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.