The AirTAC AirTAC GC300-08 FRL Unit (GC30008ANW) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$92.47 $98.45Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-08 drain, gauge and thread option on one page All GC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC300-08 FRL Unit (GC30008ANW)

The GC30008ANW is a genuine AirTAC G-series three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator assembled as one set. This configuration has PT1/4 ports, the W-code 5 um filter element for finer particle removal than the standard 40 um element, and an automatic drain on the filter bowl so condensate leaves the bowl without manual attention. The standard regulator adjusts from 0.15 to 0.9 MPa (20-130 psi) with this auto-drain arrangement, and no gauge is fitted (N code) - an external round gauge can be ordered as an option.

This is a genuine AirTAC part in the GC series, available in 200, 300, 400 and 600 sizes with ports from 1/8" to 1" and PT, G (BSPP) or NPT threads. Working pressure is up to 1.0 MPa (145 psi) and temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so we confirm the datasheet and sizing on request.

AirTAC GC300-08 FRL Unit (GC30008ANW) Technical Specifications

ModelAirTAC GC300-08 FRL Unit (GC30008ANW)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-08 FRL Unit (GC30008ANW)

GC300G-series F.R.L. combination, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-08 filter, GR300-08 regulator and GL300-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/4" · 5 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-08
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-08 FRL Unit (GC30008ANW) Is Used

science

Laboratory automation skid

Conditions air for actuated valves and small actuators on a lab skid, where the 5 um element gives finer protection to sensitive pilot components.

handyman

Furniture spray-finishing bench

Feeds spray equipment and air tools at a woodworking finishing bench, with regulated pressure, oil mist and an auto-draining fine filter in one set.

view_module

Electronics fixture clamping

Supplies pneumatic clamps on an electronics test fixture, keeping fine particles away from small valves that standard 40 um filtration would leave exposed.

Is the AirTAC GC300-08 FRL Unit (GC30008ANW) the Right Station?

Size 300 with 08 ports means a 1/4" connection - the usual step for feeding single machines or cells; drop to 200 for light duty or step to 400/600 for heavier runs. This unit pairs the 5 um (W) element with the automatic drain, which suits fine-filtration points that are not checked every day; the standard regulator covers 0.15-0.9 MPa (20-130 psi). A gauge is not fitted, but an external round gauge is an orderable option, as are G (BSPP) and NPT threads in place of the PT standard, and an optional mounting bracket.

AirTAC publishes GC flow as curves rather than a single rated figure, so ask us to confirm sizing against your pressure and consumption before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-08 regulator with a GF300-08 filter on that branch.

AirTAC GC300-08 FRL Unit (GC30008ANW) FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not state a number here. Send us your line pressure and air consumption and we will confirm the flow curve and datasheet for the GC30008ANW before you order.

The W code selects the 5 um element, which is the better pick when the downstream valves, cylinders or instruments are sensitive to fine particles; the standard 40 um element suits general plant-air duty. With this set the element sits in the filter with an automatic drain, ahead of the regulator and lubricator.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC300-08 FRL Unit (GC30008ANW)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30008ANW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.