verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC300-08 FRL Unit (GC30008MF1WK)

The AirTAC AirTAC GC300-08 FRL Unit (GC30008MF1WK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$99.03 $105.17Save 5% Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC300-08 FRL Unit (GC30008MF1WK)

The AirTAC GC series is a three-piece F.R.L. combination: a separate air filter, pressure regulator and lubricator assembled as one air-preparation set. This GC30008MF1WK is the size 300 set with PT1/4 (1/4 in) ports, a manual drain on the filter bowl, a 5 um filter element, an embedded square pressure gauge on the MPa scale, and a reverse check valve fitted. It removes water and particulate from compressed air, holds a set downstream pressure and meters oil mist into the line.

This is a genuine AirTAC part. Maximum inlet pressure is 1.0 MPa (145 psi); the regulator on this manual-drain set adjusts from 0.05 to 0.9 MPa (7-130 psi); working temperature is -5 to 70 C (non-freezing); the size 300 filter bowl is polycarbonate. The GC family is also offered in sizes 200, 400 and 600, with G (BSPP) or NPT thread options and a 40 um standard element. AirTAC publishes flow as capacity curves rather than one rated figure - ask us and we will confirm the datasheet figures for your application.

AirTAC GC300-08 FRL Unit (GC30008MF1WK) Technical Specifications

ModelAirTAC GC300-08 FRL Unit (GC30008MF1WK)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (PT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-08 FRL Unit (GC30008MF1WK)

GC300G-series F.R.L. combination, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-08 filter, GR300-08 regulator and GL300-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/4" · 5 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-08
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-08 FRL Unit (GC30008MF1WK) Is Used

valve

Control-valve positioner supply

Feeds the positioner and pilot stages of a large process control valve, where the check valve holds the prepared-air leg under pressure and the 5 um element protects the positioner orifice.

conveyor_belt

Sorter diverter air supply

Serves the diverter and stopper cylinders on a parcel sorter, with the check valve preventing backflow from the manifold and the lubricator oiling the cylinders on each divert.

science

Test-rig clamp actuators

Supplies the hold-down clamps on a laboratory or QA test rig, giving clean 5 um air, a stable set pressure held by the check valve, and light lubrication for the clamp seals.

Is the AirTAC GC300-08 FRL Unit (GC30008MF1WK) the Right Station?

Choose the GC size (200/300/400/600) to match the port and air demand of the circuit; this size 300 set carries 1/4 in PT ports. The K suffix adds a reverse check valve, so order this code when backflow into the set must be blocked; drop the K if not. Manual drain (M) means the filter bowl is bled periodically, and the manual-drain regulator covers 0.05-0.9 MPa (7-130 psi). The W element filters to 5 um for air feeding fine valves and actuators; the 40 um standard element is a separate code. The square gauge reads in MPa; a bar-scale version is a separate code. Thread is PT as standard - G (BSPP) or NPT are separate catalogue codes. Flow is published as capacity curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-08 regulator with a GF300-08 filter on that branch.

AirTAC GC300-08 FRL Unit (GC30008MF1WK) FAQ

AirTAC publishes F.R.L. capacity as flow curves rather than a single rated number, and the fitted check valve also affects the pressure profile across the set, so we do not quote a figure here. Share your line pressure and air consumption and we will confirm the datasheet curve before you order.

GC is the three-unit F.R.L. family, 300 is the size, 08 is the 1/4 in port, M is the manual drain, F1 is the embedded square gauge on the MPa scale, W is the 5 um filter element and K is the fitted reverse check valve. Thread is PT as standard; G (BSPP) and NPT versions are separate orderable codes.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC300-08 FRL Unit (GC30008MF1WK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30008MF1WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.