verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC300-10 FRL Unit (GC30010ALF1WK)

The AirTAC AirTAC GC300-10 FRL Unit (GC30010ALF1WK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$109.47 $115.87Save 5% Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC300-10 FRL Unit (GC30010ALF1WK)

GC30010ALF1WK is a genuine AirTAC G-series three-unit F.R.L. combination: separate filter, regulator and lubricator units that together clean, regulate and oil-mist lubricate a compressed-air line. This 300-size set is ported 3/8 inch with a PT thread, carries the 5 um (W) filter element with an automatic drain on the filter bowl, and is built on the low-pressure (L) type regulator with the embedded square gauge scaled in MPa. The K suffix fits a reverse (check) valve in the regulator section. At size 300 the filter and lubricator bowls are polycarbonate (PC).

AirTAC builds the G series in sizes 200, 300, 400 and 600, with differential-pressure, automatic or manual drains, 40 um or 5 um filtration, PT, G (BSPP) or NPT threads, gauge styles and scales, a low-pressure regulator option and an optional reverse valve. Maximum working pressure is 1.0 MPa (145 psi) and the temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so we confirm the datasheet and flow figures for this set on request.

AirTAC GC300-10 FRL Unit (GC30010ALF1WK) Technical Specifications

ModelAirTAC GC300-10 FRL Unit (GC30010ALF1WK)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-10 FRL Unit (GC30010ALF1WK)

GC300G-series F.R.L. combination, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-10 filter, GR300-10 regulator and GL300-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT3/8" · 5 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-10
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-10 FRL Unit (GC30010ALF1WK) Is Used

build

Fixture clamping on a machining centre

Supplying power clamps on a machining-centre fixture, where the fitted check valve helps hold the clamped circuit if the shop air supply dips mid-cycle.

local_shipping

Dock leveller ram circuit

Conditioning the air feeding a pneumatic dock leveller or lift-assist ram, with the check valve limiting back-flow when the upstream supply is shut down.

settings_input_component

Palletiser hold circuits

Holding position on the clamp and pusher circuits of a palletiser, where the check valve limits back-flow if upstream pressure is lost during a cycle.

Is the AirTAC GC300-10 FRL Unit (GC30010ALF1WK) the Right Station?

Size 300 with a 3/8 inch PT port is the mid step of the range; step to 200 for small drops or to 400/600 for larger mains and higher air demand. The W suffix selects the 5 um element, with the standard 40 um grade available for coarse protection, and the A suffix fits an automatic drain (manual and differential-pressure are alternatives). This is the low-pressure (L) type regulator; with the automatic drain the catalogue set range is 0.15-0.9 MPa (20-130 psi). The K suffix is the key choice here: it adds a reverse (check) valve so the downstream circuit is not vented back through the set if the supply dips - leave K out if you do not need that hold function. The embedded square gauge reads in MPa, with other scales and the round gauge orderable. PT is the standard thread, with G and NPT as catalogue options. Flow is published only as curves, so ask us to confirm sizing before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-10 regulator with a GF300-10 filter on that branch.

AirTAC GC300-10 FRL Unit (GC30010ALF1WK) FAQ

AirTAC publishes G-series flow as curves against pressure rather than a single rated figure, so we do not quote one number here. Send us your working pressure and air demand and we will confirm the flow data for this 3/8 inch PT set from the datasheet before you order.

K fits a reverse (check) valve in the regulator section. It blocks back-flow through the unit, helping hold downstream pressure if the upstream supply dips or is shut off - useful on clamping and holding circuits. If you do not need that function, order the same set without the K suffix.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC300-10 FRL Unit (GC30010ALF1WK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30010ALF1WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.