The AirTAC AirTAC GC300-10 FRL Unit (GC30010C3K) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC series is a three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator piped as one set, so compressed air is cleaned, regulated and oil-mist lubricated before it reaches your valves, cylinders and air tools. This GC30010C3K is the size 300 frame with PT3/8 ports, the standard 40 um filter element and a differential-pressure drain on the filter bowl. The regulator carries the C3 gauge option, an external round gauge with a bar scale, and the K option adds a reverse check valve so air cannot flow back through the set. Maximum inlet pressure is 1.0 MPa (145 psi) and the regulator adjusting range with the differential-pressure drain is 0.15-0.9 MPa (20-130 psi). Operating temperature is -5 to 70 C, non-freezing.
This is a genuine AirTAC part supplied by an authorised distributor. The GC series spans sizes 200, 300, 400 and 600 with matching port sizes, and the same frame can be ordered with a 5 um element (W), automatic or manual drain, a square embedded gauge in MPa, psi or bar scales, or G (BSPP) and NPT threads instead of PT. Rated flow is published as curves rather than a single figure, so ask us to confirm sizing and datasheet details for your application before ordering.
| Model | AirTAC GC300-10 FRL Unit (GC30010C3K) |
|---|---|
| Series | GC300 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT3/8" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, bar scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC300 | G-series F.R.L. combination, 300 body — sets the port range. |
|---|---|
| 10 | Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 3 | Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-10 filter, GR300-10 regulator and GL300-10 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC300 · PT3/8" · 40 µm |
|---|---|
| One size down | GC200 |
| One size up | GC400 |
| Two-unit equivalent | GFC300-10 |
| Build order | Filter → regulator → lubricator |
Feeds filtered, regulated and lubricated air to the tool-clamp cylinders, chip-door actuators and directional valves on a machining centre's shop-air drop, with the check valve blocking backflow in the branch.
Supplies the carton-sealing and case-packing cylinders on a packaging conveyor, keeping the air dry and oil-misted so flap-tuck and press cylinders cycle smoothly through long shifts.
Conditions the air feeding impact wrenches, nutrunners and air ratchets at an assembly station, where the lubricator's oil mist protects tool motors and the regulator holds a steady working pressure.
Size 300 with 3/8 in. ports sits in the middle of the GC range; step up to 400/600 or down to 200/100-class ports as your line flow demands. The 40 um element is the standard grade; choose the W suffix for 5 um when downstream valves need finer filtration. The differential-pressure drain used here is the default; automatic (A) and manual (M) drain variants are also orderable. This code specifies the C3 external round gauge with a bar scale; square embedded gauges in MPa, psi or bar scales are alternatives. PT thread is the standard for this code, with G (BSPP) and NPT available as catalogue options, and the K suffix fits a reverse check valve. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-10 regulator with a GF300-10 filter on that branch.
AirTAC publishes flow for the GC series as performance curves rather than a single rated number, so we do not quote one figure here. Tell us your line pressure and air demand and we will confirm the correct size from the datasheet curves on request.
C3 specifies an external round pressure gauge with a bar scale on the regulator, and K means a reverse check valve is fitted in the set. The filter uses the standard 40 um element with a differential-pressure drain; 5 um (W) and automatic or manual drain versions are separate orderable codes.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.