The AirTAC AirTAC GC300-10 FRL Unit (GC30010F1K) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC series is a three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator assembled as one set, cleaning, regulating and oil-mist lubricating compressed air before it reaches your actuators and valves. This GC30010F1K is the size 300 frame with PT3/8 ports, the standard 40 um filter element and a differential-pressure drain, with the regulator's embedded square gauge on an MPa scale (the F1 option). The K option adds a reverse check valve so air cannot flow back through the set toward the supply side. Maximum inlet pressure is 1.0 MPa (145 psi), the regulator adjusting range with the differential-pressure drain is 0.15-0.9 MPa (20-130 psi), and the working temperature is -5 to 70 C, non-freezing. The size 300 bowls are PC (polycarbonate).
This is a genuine AirTAC part. The GC series spans sizes 200 to 600 with matching ports, and the same set is available with a 5 um element (W), automatic or manual drain, an external round gauge or psi and bar scales, and G (BSPP) or NPT threads in place of the PT standard. Flow is published as curves rather than a single rating, so ask us to confirm datasheet figures and sizing on request before ordering.
| Model | AirTAC GC300-10 FRL Unit (GC30010F1K) |
|---|---|
| Series | GC300 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT3/8" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC300 | G-series F.R.L. combination, 300 body — sets the port range. |
|---|---|
| 10 | Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-10 filter, GR300-10 regulator and GL300-10 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC300 · PT3/8" · 40 µm |
|---|---|
| One size down | GC200 |
| One size up | GC400 |
| Two-unit equivalent | GFC300-10 |
| Build order | Filter → regulator → lubricator |
Conditions the air feeding counterbalance and part-ejection cylinders on a stamping press, with the check valve preventing backflow through the set and the regulator holding the balance pressure.
Supplies the diverter and pusher cylinders along a sortation conveyor, delivering filtered, regulated, lubricated air for thousands of divert cycles, with the reverse valve isolating the branch.
Feeds the wire-feed clamps and cut-off slides on a cold-forming fastener machine, where steady regulated pressure and oil mist keep the high-cycle cylinders moving reliably.
Choose this code when you want the standard size 300 F.R.L. with the F1 embedded square MPa gauge plus the K reverse check valve in one order; the equivalent set without the valve is GC30010F1. The 40 um element and differential-pressure drain are the defaults, with 5 um (W) and automatic or manual drain codes as alternatives. Size 300 with 3/8 in. ports is the mid-range frame; move up or down the 200-600 range as your branch flow demands, and order G (BSPP) or NPT threads if your piping is not PT. Because GC flow is published as curves, not a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-10 regulator with a GF300-10 filter on that branch.
AirTAC publishes GC-series flow as performance curves rather than one rated figure, so we do not quote a number here. Give us your working pressure and air consumption and we will confirm from the datasheet that size 300 with 3/8 in. ports suits your application.
K means a reverse check valve is fitted, so air cannot flow backwards through the set toward the supply side. Otherwise this is the size 300 standard build: PT3/8 ports, 40 um element, differential-pressure drain and the embedded square gauge reading in MPa.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.