The AirTAC AirTAC GC300-10 FRL Unit (GC30010F3) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC series is AirTAC's three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator delivered as one matched set. This GC30010F3 is the size 300 frame with PT3/8 standard ports, fine 5 um filtration (W grade), a differential-pressure drain on the filter bowl, and an embedded square gauge scaled in bar. It cleans, regulates and lubricates the compressed air supply in a single installation, with a maximum working pressure of 1.0 MPa (145 psi) and an operating range of -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The G series covers sizes 200, 300, 400 and 600, with 40 um or 5 um filtration, differential-pressure, automatic or manual drains, and G (BSPP) or NPT threads as order options; 300-size bowls are polycarbonate. AirTAC publishes flow as curves rather than a single rated figure, so ask us and we will confirm the datasheet figures for your application.
| Model | AirTAC GC300-10 FRL Unit (GC30010F3) |
|---|---|
| Series | GC300 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT3/8" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, bar scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC300 | G-series F.R.L. combination, 300 body — sets the port range. |
|---|---|
| 10 | Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 3 | Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-10 filter, GR300-10 regulator and GL300-10 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC300 · PT3/8" · 40 µm |
|---|---|
| One size down | GC200 |
| One size up | GC400 |
| Two-unit equivalent | GFC300-10 |
| Build order | Filter → regulator → lubricator |
Conditioning supply air for core pulls, ejectors and mold clamps on an injection molding machine, with the bar-scaled gauge matching the pressure readouts on European-specified equipment.
Feeding regulated, filtered and lubricated air to the pneumatic functions of a laser cutting cell, where consistent downstream pressure at the treatment point supports stable machine operation.
Supplying treated air to the doffing, tying and cleaning stations at individual looms in a textile plant, with each drop set locally on its own bar-scale gauge.
Size 300 with PT3/8 ports sits mid-range in the GC line; step to 200 for compact drops or 400/600 for higher demand, and we will check the published flow curves against your requirement before you order. The differential-pressure drain fitted here is the standard option; automatic (A) and manual (M) drains can be ordered instead. Filtration is the 5 um (W) element, with the standard 40 um element as the alternative. The F3 suffix selects the square gauge with a bar scale; MPa and psi scales are also available. Thread is PT as standard, with G (BSPP) and NPT as catalogue options.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-10 regulator with a GF300-10 filter on that branch.
Flow for the G series is published by AirTAC as curves, not as a single rated figure, so we do not state a number here. Share your operating pressure and consumption and we will confirm the datasheet flow data for this exact unit before you order.
Differential-pressure drainage is the standard arrangement: the bowl drains when the pressure differential across the filter rises sufficiently. If you want the bowl emptied without that trigger, order code A for an automatic drain or code M for a manual drain on the same size 300, PT3/8 set.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.